Installing The Fbwc Module And Capacitor Pack - HP ProLiant ML310e User Manual

V2 server
Hide thumbs Also See for ProLiant ML310e:
Table of Contents

Advertisement

Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Unlock the tower bezel (on page 17).
3.
Remove the access panel (on page 18).
4.
Remove the air baffle (on page 19).
5.
If necessary, disconnect the Mini-SAS cable from the system board.
6.
Install the storage controller.
7.
Connect all necessary internal and external cabling to the option. For more information on these
8.
cabling requirements, see the documentation that ships with the option. For internal cable routing
information in different drive configurations, see "Storage cabling (on page 60)."
Install the air baffle (on page 20).
9.
Install the access panel (on page 19).
10.
Install the drives
11.
CAUTION:
all bays are populated with a component or a blank.
Lock the tower bezel.
12.
Connect each power cord to the server.
13.
Connect each power cord to the power source.
14.
Power up the server (on page 16).
15.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (http://www.hp.com/support/CASAC_RG_en).
Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs
on the HP website (http://www.hp.com/support).

Installing the FBWC module and capacitor pack

CAUTION:
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the external drives as failed when the server is powered up.
To install the component:
Power down the server (on page 16).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Unlock the tower bezel (on page 17).
3.
Remove the access panel (on page 18).
4.
Remove the air baffle (on page 19).
5.
("Drive
options" on page 28).
To prevent improper cooling and thermal damage, do not operate the chassis unless
In systems that use external data storage, be sure that the server is the first unit to be
Hardware options installation 37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml310e gen8 v2

Table of Contents