Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 682266-001
September 2012
Edition: 1

Advertisement

Table of Contents
loading

Summary of Contents for HP ProLiant ML310e

  • Page 1: User Guide

    HP ProLiant ML310e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
  • Page 2 Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation. Bluetooth® is a trademark owned by its proprietor and used by Hewlett-Packard Company under license. Intel® Xeon®, Pentium®, Celeron®, and Intel® Core™ are trademarks of Intel Corporation in the U.S. and other countries.
  • Page 3: Table Of Contents

    Contents Component identification ....................... 7 Front panel components ..........................7 Front panel LEDs and buttons ......................8 Rear panel components ..........................9 Rear panel LEDs and buttons ......................10 System board components ........................11 DIMM slot locations ........................12 PCIe expansion slot definitions ......................12 System maintenance switch ......................
  • Page 4 Drive installation guidelines ......................30 Installing a non-hot-plug drive ......................30 Installing a hot-plug drive ........................ 32 Drive cage options ..........................33 Four-bay LFF hot-plug drive backplane option ..................33 Eight-bay SFF hot-plug drive cage option ..................37 Controller options ............................ 39 Installing a storage controller ......................
  • Page 5 Array Configuration Utility ......................74 Option ROM Configuration for Arrays ..................... 75 ROMPaq utility ..........................76 Automatic Server Recovery ......................76 USB support ..........................76 Redundant ROM support ........................ 76 Keeping the system current ........................77 Drivers ............................77 Software and firmware ........................77 Version control ..........................
  • Page 6 Before you contact HP ..........................92 HP contact information ..........................92 Customer Self Repair ..........................92 Acronyms and abbreviations ...................... 100 Documentation feedback ......................104 Index ............................105 Contents 6...
  • Page 7: Component Identification

    Component identification Front panel components Item Description Optical drive (optional) Media drive bay USB connectors Power On/Standby button and system power LED Drive bays (inside) Component identification 7...
  • Page 8: Front Panel Leds And Buttons

    Front panel LEDs and buttons Item Description Status UID LED button Blue = Identification is activated Flashing blue = System is being managed remotely Off = Identification is deactivated Health LED Green = Normal (system on) Flashing amber = System health is degraded Flashing red = System health is critical Off = Normal (system off) NIC status LED...
  • Page 9: Rear Panel Components

    Rear panel components Item Description Non-hot-plug power supply Slot 4 PCIe x16 (8, 4, 1)* Slot 3 PCIe x8 (8, 4, 1)* Slot 2 PCIe x8 (4, 1)* Slot 1 PCIe x4 (1)* Expansion slot cover retainer Serial connector Video connector Dedicated iLO management port (optional) NIC 1/shared iLO management connector NIC connector 2...
  • Page 10: Rear Panel Leds And Buttons

    Rear panel LEDs and buttons Item Description Status NIC link LED Green = Link exists Off = No link exists NIC status LED Green = Activity exists Flashing green = Activity exists Off = No activity exists UID LED button Blue = Identification is activated Flashing blue = System is being managed remotely...
  • Page 11: System Board Components

    System board components Item Description RPS connector Processor socket System battery 24-pin power supply connector Mini-SAS connector SATA connectors Internal USB cable connector Internal USB connector SD card slot Front USB connector 2 Front USB connector 1 Front panel LED connector Fan connector 2 Reserved Ambient thermal sensor connector...
  • Page 12: Dimm Slot Locations

    * For more information on the expansion slot specifications, see "PCIe expansion slot definitions (on page 12)." DIMM slot locations DIMM slots are numbered sequentially (1 through 4) for the processor. The supported AMP modes use the letter assignments for population guidelines. PCIe expansion slot definitions The transfer rate of the PCIe expansion slots 3 and 4 depends on the processor model installed.
  • Page 13: Nmi Header

    Switch Default Function Off = System configuration can be changed On = System configuration is locked Off = Power-on password is enabled On = Power-on password is disabled Off = No function On = ROM reads configuration as invalid — Reserved 3, 4, 7, 8, 9, 10, 11, 12...
  • Page 14: Drive Numbering

    Drive numbering • Four-bay LFF drive model • Eight-bay SFF drive model Component identification 14...
  • Page 15: Drive Led Definitions

    Drive LED definitions Item Status Definition Locate Solid blue The drive is being identified by a host application. Flashing blue The drive carrier firmware is being updated or requires an update. Activity ring Rotating green Drive activity No drive activity Do not remove Solid white Do not remove the drive.
  • Page 16: Fbwc Module Led Definitions

    FBWC module LED definitions The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing. 1 - Amber 2 - Green 3 - Green Interpretation The cache module is not powered.
  • Page 17: Fan Locations

    Fan locations Item Description Rear system fan (fan 1, for processor cooling) Front system fan (fan 2, for expansion board cooling) T-10/T-15 Torx screwdriver The server includes a T-10/T-15 Torx screwdriver located on the side of the media drive cage. Use the screwdriver to loosen screws during hardware configuration procedures.
  • Page 18: Operations

    Operations Power up the server Connect each power cord to the server. Connect each power cord to the power source. Press the Power On/Standby button. The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.
  • Page 19: Unlock The Tower Bezel

    Unlock the tower bezel The tower bezel must be unlocked and opened to access the drive cage and media bays. It must be unlocked to remove the access panel. The bezel must remain closed during normal server operations. Remove the tower bezel Unlock and open the tower bezel ("Unlock the tower bezel"...
  • Page 20: Remove The Access Panel

    Close and lock the tower bezel. Remove the access panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed.
  • Page 21: Install The Access Panel

    Lift the access panel away from the chassis. Install the access panel Install the access panel: Place the access panel on the chassis, and slide it toward the front of the server. Tighten the thumbscrew. Lock the tower bezel. Remove the air baffle CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed.
  • Page 22: Install The Air Baffle

    Power down the server (on page 18). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Unlock the tower bezel (on page 19). Remove the access panel (on page 20). Remove the air baffle. Install the air baffle Insert the tabs on the baffle to the slots on the rear chassis.
  • Page 23 Lock the tower bezel. Power up the server (on page 18). Operations 23...
  • Page 24: Setup

    Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.
  • Page 25: Space And Airflow Requirements

    Space and airflow requirements Leave at least a 7.6-cm (3-inch) clearance space at the front and back of the server for proper ventilation. Temperature requirements To ensure continued, safe, and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment.
  • Page 26: Server Warnings And Cautions

    includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended. Server warnings and cautions WARNING: This server is very heavy.
  • Page 27: Identifying The Contents Of The Server Shipping Carton

    WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack: • At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might become unstable when being moved on its casters.
  • Page 28: Installing The Operating System

    WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment: Observe local occupational health and safety requirements and guidelines for manual • material handling. • Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails.
  • Page 29: Powering On And Selecting Boot Options

    Connect the Ethernet cable, and then power on the server. During server POST, press the F10 key. Complete the initial Preferences and Registration portion of Intelligent Provisioning (on page 69). At the 1 Start screen, click the Configure and Install button. To finish the installation, follow the onscreen prompts.
  • Page 30: Hardware Options Installation

    Hardware options installation Introduction If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  • Page 31 Remove the drive carrier. Remove the two metal brackets from the drive carrier. Install the drive in the carrier. Hardware options installation 31...
  • Page 32: Installing A Hot-Plug Drive

    Install the drive. Close and lock the tower bezel. Connect each power cord to the server. Connect each power cord to the power source. Power up the server (on page 18). Installing a hot-plug drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
  • Page 33: Drive Cage Options

    Prepare the drive. Install the drive. Determine the status of the drive from the drive LED definitions (on page 15). Close and lock the tower bezel. Drive cage options Four-bay LFF hot-plug drive backplane option To install the component: Power down the server (on page 18). Remove all power: Disconnect each power cord from the power source.
  • Page 34 Disconnect the drive cage cables: Disconnect the Mini-SAS cable from the system board or from the storage controller option. Disconnect the drive power cable from the 10-pin power supply connector. Remove the drive cage assembly. Loosen the bracket thumbscrew, and then remove the non-hot-plug bracket assembly from the drive cage.
  • Page 35 Attach the hot-plug drive backplane to the drive cage, and then tighten the thumbscrew. Install the drive cage assembly. Connect the drive backplane cables: Connect the power cable to the backplane. Do one of the following: — Connect the Mini-SAS cable to the system board (SATA drive support only). Hardware options installation 35...
  • Page 36 For cable routing information, see "Hot-plug, SATA drive support (on page 62)." — Connect one end of the Mini-SAS cable to the backplane and the other end to a storage controller option (SATA and SAS drive support). For cable routing information, see "Hot-plug, SATA and SAS drive support (on page 63)." Install the drives ("Drive options"...
  • Page 37: Eight-Bay Sff Hot-Plug Drive Cage Option

    Power up the server (on page 18). Eight-bay SFF hot-plug drive cage option To install the component: Power down the server (on page 18). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Remove the tower bezel (on page 19).
  • Page 38 Install the SFF drive cage assembly. Connect the drive backplane cables: Connect the power cable to the backplane. Connect the Mini-SAS cables to the backplane and to a storage controller option. For cable routing information, see "Eight-bay SFF drive cabling (on page 63)." Install the drives ("Drive options"...
  • Page 39: Controller Options

    Connect each power cord to the power source. Power up the server (on page 18). Controller options The server ships with an embedded Smart Array B120i controller. For more information about the controller and its features, see the HP Dynamic Smart Array RAID Controller User Guide on the HP website (http://www.hp.com/support/DSA_RAID_UG_en).
  • Page 40: Installing The Fbwc Module And Capacitor Pack

    Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Unlock the tower bezel (on page 19). Remove the access panel (on page 20). Remove the air baffle (on page 21). If necessary, disconnect the Mini-SAS cable from the system board. Install the storage controller.
  • Page 41 Install the cache module on the storage controller. Connect the capacitor pack cable to the cache module. Install the storage controller ("Installing a storage controller" on page 39). Hardware options installation 41...
  • Page 42: Optical Drive Option

    Install the capacitor pack. Install the air baffle (on page 22). Install the access panel (on page 21). Lock the tower bezel. Connect each power cord to the server. Connect each power cord to the power source. Power up the server (on page 18). Optical drive option To install the component: Power down the server (on page 18).
  • Page 43 Remove the media bay blank. Remove the EMI shield. Hardware options installation 43...
  • Page 44: Memory Options

    Install the optical drive into the media drive bay. Connect the drive cables: Connect the power cable to the drive. Connect one end of the SATA cable to the drive and the other end to the system board. For cable routing information, see "Media drive cabling (on page 64)." Install the access panel (on page 21).
  • Page 45: Hp Smartmemory

    IMPORTANT: This server does not support mixing LRDIMMs, RDIMMs, or UDIMMs. Attempting to mix any combination of these DIMMs can cause the server to halt during BIOS initialization. The server supports single- and dual-rank UDIMMs operating at a speed of up to 1600 MHz. Depending on the processor model and the number of DIMMs installed, the memory clock speed might be reduced to 1333 or 1066 MHz.
  • Page 46: Single-Rank And Dual-Rank Dimms

    Item Description Definition Voltage rating L = Low voltage (1.35V) U = Ultra low voltage (1.25V) Blank or omitted = Standard Memory speed 12800 = 1600-MT/s 10600 = 1333-MT/s 8500 = 1066-MT/s DIMM type R = RDIMM (registered) E = UDIMM (unbuffered with ECC) L = LRDIMM (load reduced) For the latest supported memory information, see the QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html).
  • Page 47: General Dimm Slot Population Guidelines

    General DIMM slot population guidelines • The server has four memory slots. • The server supports two channels with two DIMM slots per channel. Memory channel 1 consists of the two DIMMs that are closest to the processor. Memory channel 2 consists of the two DIMMs that are farthest from the processor. •...
  • Page 48: Expansion Board Options

    Install the DIMM. Install the air baffle (on page 22). Install the access panel (on page 21). Lock the tower bezel. Connect each power cord to the server. Connect each power cord to the power source. Power up the server (on page 18). After installing the DIMMs, to configure the memory protection mode, use RBSU ("HP ROM-Based Setup Utility"...
  • Page 49 Remove the expansion slot cover retainer. Identify the expansion slot compatible with the new option, and then remove the cover opposite that slot. Hardware options installation 49...
  • Page 50 If installing a full-length expansion board, remove the board retainer. Install the expansion board. Hardware options installation 50...
  • Page 51 If installing a full-length expansion board, install back the board retainer. Install the expansion slot cover retainer. Connect all necessary internal and external cables to the expansion board. For more information on these cabling requirements, see the documentation that ships with the option. Install the air baffle (on page 22).
  • Page 52: Dedicated Ilo Management Port Option

    Dedicated iLO management port option To install the component: Power down the server (on page 18). Unlock the tower bezel (on page 19). Remove the access panel (on page 20). Remove the air baffle (on page 21). Remove any existing expansion board that blocks the access to the rear system fan connector. Remove the rear system fan.
  • Page 53: Enabling The Dedicated Ilo Management Port

    Install the dedicated iLO management module. Install the rear system fan. Install any removed expansion board. Install the air baffle (on page 22). Install the access panel (on page 21). Lock the tower bezel. Connect each power cord to the server. Connect each power cord to the power source.
  • Page 54: Hp Trusted Platform Module Option

    HP Trusted Platform Module option Use these instructions to install and enable a TPM on a supported server. This procedure includes three sections: Installing the Trusted Platform Module board (on page 54). Retaining the recovery key/password (on page 56). Enabling the Trusted Platform Module (on page 56). Enabling the TPM requires accessing RBSU ("HP ROM-Based Setup Utility"...
  • Page 55 Remove the air baffle (on page 21). Remove any existing expansion board that blocks the access to the rear system fan connector. Remove the rear system fan. CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet.
  • Page 56: Retaining The Recovery Key/Password

    Install the TPM security rivet by pressing the rivet firmly into the system board. Install the rear system fan. Install any removed expansion board. Install the air baffle (on page 22). Install the access panel (on page 21). Lock the tower bezel. Connect each power cord to the server.
  • Page 57: Rps Enablement Option

    Select Enable, and then press the Enter key to modify the TPM Functionality setting. Press the Esc key to exit the current menu, or press the F10 key to exit RBSU. Reboot the server. Enable the TPM in the OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system...
  • Page 58 Remove the power supply. Disconnect all cables from installed media drives. Remove all installed devices and any EMI shields from the media drive bays. Install the RPS cage. Hardware options installation 58...
  • Page 59 Insert the RPS backplane module cables into the media drive cage, and then slide in the module into the lower media drive bay. Align the left edge of the module with the guide mark on the bay. Connect the eight-pin to four-pin adapter cable to the eight-pin power supply connector of the RPS backplane module.
  • Page 60 Remove the EMI shield. Install the HP CS power supplies. Install any device originally installed in the upper media drive bay. Install the EMI shield in the lower media drive bay. Install the access panel (on page 21). If the lower media bay blank is not attached to the tower bezel, install it. Lock the tower bezel.
  • Page 61: Cabling

    Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance. For information on cabling peripheral components, refer to the white paper on high-density deployment at the HP website (http://www.hp.com/products/servers/platforms). CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.
  • Page 62 Non-hot-plug, SATA and SAS drive support Item Description Power cable Data cable Hot-plug, SATA drive support Item Description Power cable Mini-SAS cable Cabling 62...
  • Page 63: Eight-Bay Sff Drive Cabling

    Hot-plug, SATA and SAS drive support Item Description Power cable Mini-SAS cable Eight-bay SFF drive cabling This drive configuration supports hot-plug SATA and SAS drives. Item Description Power cable Mini-SAS cable Mini-SAS cable Cabling 63...
  • Page 64: Media Drive Cabling

    Media drive cabling • Media drives in a nonredundant power configuration Item Description Upper media drive power cable Lower media drive SATA cable Upper media drive SATA cable Lower media drive power cable • Media drive in a redundant power configuration Item Description Upper media drive SATA cable...
  • Page 65: Power Supply Cabling

    Power supply cabling Nonredundant power supply cabling Item Description 24-pin power supply cable 4-pin power supply cable Redundant power supply cabling Item Description 24-pin power supply cable 26-pin RPS cable Cabling 65...
  • Page 66: Capacitor Pack Cabling

    Item Description 4-pin power supply cable (with the 8-pin to 4-pin adapter cable connected) Capacitor pack cabling Cabling 66...
  • Page 67: Software And Configuration Utilities

    Software and configuration utilities Server mode The software and configuration utilities presented in this section operate in online mode, offline mode, or in both modes. Software or configuration utility Server mode Online and Offline HP iLO (on page 67) Online and Offline Active Health System (on page 68) Online and Offline Integrated Management Log (on page 69)
  • Page 68: Active Health System

    iLO enables and manages the Active Health System (on page 68) and also features Agentless Management. All key internal subsystems are monitored by iLO. SNMP alerts are sent directly by iLO regardless of the host operating system or even if no host operating system is installed. HP Insight Remote Support software (on page 71) is also available in HP iLO with no operating system software, drivers, or agents.
  • Page 69: Intelligent Provisioning

    The data that is collected is managed according to the HP Data Privacy policy. For more information see the HP website (http://www.hp.com/go/privacy). The Active Health System log, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components.
  • Page 70: Hp Insight Diagnostics

    HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation. HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS is not running.
  • Page 71: Hp Insight Remote Support Software

    HP Insight Remote Support software HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or HP contractual support agreement. HP Insight Remote Support supplements your monitoring 24 x 7 to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level.
  • Page 72: Hp Service Pack For Proliant

    HP Service Pack for ProLiant SPP is a release set that contains a comprehensive collection of firmware and system software components, all tested together as a single solution stack for HP ProLiant servers, their options, BladeSystem enclosures, and limited HP external storage. SPP has several key features for updating HP ProLiant servers.
  • Page 73: Using Rbsu

    • Configuring memory options • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/rbsu). Using RBSU To use RBSU, use the following keys: • To access RBSU, press the F9 key during power-up when prompted. •...
  • Page 74: Boot Options

    Boot options Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following: •...
  • Page 75: Option Rom Configuration For Arrays

    Advanced Capacity Expansion (SATA to SAS and SAS to SATA) Offline Split Mirror RAID 6 and RAID 60 RAID 1 (ADM) and RAID 10 (ADM) HP Drive Erase Video-On-Demand Advanced Controller Settings • Provides different operating modes, enabling faster configuration or greater control over the configuration options •...
  • Page 76: Rompaq Utility

    For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en).
  • Page 77: Keeping The System Current

    NOTE: The server ships with the same version programmed on each side of the ROM. Safety and security benefits When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason.
  • Page 78: Hp Operating Systems And Virtualization Software Support For Proliant Servers

    For more information about version control tools, see the HP Systems Insight Manager User Guide, the HP Version Control Agent User Guide, and the HP Version Control Repository User Guide on the HP website (http://www.hp.com/go/hpsim). HP Operating Systems and Virtualization Software Support for ProLiant Servers For information about specific versions of a supported operating system, see the HP website (http://www.hp.com/go/ossupport).
  • Page 79: Troubleshooting

    Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language: •...
  • Page 80: System Battery Replacement

    System battery replacement If the server no longer automatically displays the correct date and time, you might have to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years. WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack.
  • Page 81 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. System battery replacement 81...
  • Page 82: Regulatory Compliance Notices

    Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number.
  • Page 83: Declaration Of Conformity For Products Marked With The Fcc Logo, United States Only

    Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
  • Page 84: European Union Regulatory Notice

    CE and !). Please refer to the regulatory label provided on the product. The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, GERMANY. Disposal of waste equipment by users in private...
  • Page 85: Japanese Notice

    This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
  • Page 86: Chinese Notice

    Class B equipment Chinese notice Class A equipment Vietnam compliance marking notice This marking is for applicable products only. Ukraine notice Laser compliance This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver.
  • Page 87: Battery Replacement Notice

    WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation: Do not try to open the module enclosure. There are no user-serviceable components inside. •...
  • Page 88: Acoustics Statement For Germany (Geräuschemission)

    Acoustics statement for Germany (Geräuschemission) Schalldruckpegel L < 70 dB(A) Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprüfung) Regulatory compliance notices 88...
  • Page 89: Electrostatic Discharge

    Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 90: Specifications

    Specifications Environmental specifications Specification Value Temperature range* 10°C to 35°C (50°F to 95°F) Operating -30°C to 60°C (-22°F to 140°F) Nonoperating Relative humidity (noncondensing) 10% to 90% Operating, maximum wet bulb temperature of 28°C (82.4°F) 5% to 95% Nonoperating, maximum wet bulb temperature of 38.7°C (101.7°F) * All temperature ratings shown are for sea level.
  • Page 91: Hp 350 W 4U Factory Integrated Power Supply

    HP 350 W 4U Factory Integrated Power Supply Specification Value — Input requirements 100 V AC to 240 V AC Rated input voltage 47 Hz to 63 Hz Rated input frequency Rated input current 440 W at 100 V AC input Rated input power 440 W at 200 V AC input No less than 82% at 100% load...
  • Page 92: Support And Other Resources

    Support and other resources Before you contact HP Be sure to have the following information available before you call HP: • Active Health System log Download and have available an Active Health System log for 3 days before the failure was detected. For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs).
  • Page 93 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts: • Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.
  • Page 94 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP (http://www.hp.com/go/selfrepair). Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair).
  • Page 95 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet. CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar.
  • Page 96 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio. Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local.
  • Page 97 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto. OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente.
  • Page 98 Support and other resources 98...
  • Page 99 Support and other resources 99...
  • Page 100: Acronyms And Abbreviations

    Acronyms and abbreviations ABEND abnormal end Array Configuration Utility Advanced Memory Protection Automatic Server Recovery baseboard management controller BSMI Bureau of Standards, Metrology and Inspection Conformité Européenne (European Conformity) Canadian Standards Association Customer Self Repair double data rate electromagnetic interference FBWC flash-backed write cache Acronyms and abbreviations 100...
  • Page 101 Federal Communications Commission HP CS HP Common Slot (power supply) HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager International Electrotechnical Commission Integrated Lights-Out Integrated Management Log International Organization for Standardization large form factor LRDIMM load reduced dual in-line memory module nonmaskable interrupt NVRAM nonvolatile memory...
  • Page 102 power distribution unit POST Power-On Self Test preboot execution environment RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module Rapid Deployment Pack radio frequency radio frequency interference redundant power supply serial attached SCSI SATA serial ATA Secure Digital small form factor HP Service Pack for ProLiant Acronyms and abbreviations 102...
  • Page 103 TMRA recommended ambient operating temperature Trusted Platform Module UDIMM unregistered dual in-line memory module unit identification universal serial bus Version Control Agent VCRM Version Control Repository Manager Acronyms and abbreviations 103...
  • Page 104: Documentation Feedback

    Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 104...
  • Page 105: Index

    Index access panel 20, 21 dedicated iLO management connector 52, 53 air baffle 21, 22 device numbers 14 Array Configuration Utility (ACU) 74 diagnostic tools 67, 70, 76 ASR (Automatic Server Recovery) 76 diagnostics utility 70 authorized reseller 92 DIMM identification 45 auto-configuration process 73 DIMM population guidelines 47 Automatic Server Recovery (ASR) 76...
  • Page 106 LEDs, unit identification (UID) 8 LFF backplane 33 grounding methods 89 LFF drive cage 33 grounding requirements 25 location 17 guidelines 30, 47 media drive bay 42 hard drives, installing 30, 32 media drive bay cabling 64 hardware options installation 30 memory 45, 46 health driver 76 memory options 30, 44...
  • Page 107 specifications, power 90 specifications, server 90 QuickSpecs 67 static electricity 89 storage controller 39 support 92 supported operating systems 78 rack installation 24, 27 switch, system maintenance 12 rack resources 24 system battery 80 rack warnings 26 system board components 11 RBSU (ROM-Based Setup Utility) 67, 72, 73, 74 system components 7 rear components 9...

This manual is also suitable for:

Proliant ml310e gen8

Table of Contents