Installing The Fbwc Module And Capacitor Pack - HP ProLiant DL100 Series User Manual

Proliant dl100 series server
Hide thumbs Also See for ProLiant DL100 Series:
Table of Contents

Advertisement

Install the battery pack.
7.
Route the cable.
8.
Install the access panel.
9.
Install the server into the rack.
10.

Installing the FBWC module and capacitor pack

To install the component:
CAUTION:
models, because the controller can malfunction and you can lose data. Also, do not transfer
this cache module to a different controller module, because you can lose data.
Back up all data.
1.
Close all applications.
2.
Power down the server (on page 15).
3.
CAUTION:
be powered down and the last to be powered back up. Taking this precaution ensures that
the system does not erroneously mark the drives as failed when the server is powered up.
Remove the server from the rack (on page 15).
4.
Remove the access panel (on page 16).
5.
Install the storage controller, if not installed
6.
Do not use this controller with cache modules designed for other controller
In systems that use external data storage, be sure that the server is the first unit to
("Storage controller
option" on page 37).