3 - MAINTENANCE

ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIED
DISCONNECT THE POWER SOURCE FROM THE MAINS BEFORE PERFORMING

3.1 - Periodic inspection, cleaning.

Periodically remove any dirt or dust from the air vents to ensure smooth air flow, and thus
adequate cooling of the internal parts of the power source.
Check the condition of the output terminals, output and power supply cables of the power
source; replace if damaged.
Check the condition of the internal power connections and connectors on the electronic board;
if you find "loose" connections, tighten or replace the connectors.

3.2 - Sequence of operations (fig. 3.2.1).

The following sequence represents correct functioning of the machine. It may be used as a
guiding procedure for troubleshooting.
It must be carried out after each repair without any errors.
Operations preceded by this symbol refer to operator actions.
q
♦ Operations preceded by this symbol refer to machine responses that must occur following an
operator action.

3.2.1 - Power source commands and signals.