Olivetti d-Color MF 552 plus Installation Manual page 25

Hide thumbs Also See for d-Color MF 552 plus:
Table of Contents

Advertisement

XXXI. Performing Non-Image Area Erase
Check
Note:
Perform the below at the site where customer
uses the machine.
1. Display the Service Mode screen.
(For details of how to display the Service Mode
screen, see the service manual.)
2. Select the Non-Image Area Erase Check function
as follows:
Machine → Non-Image Area Erase Check.
Note:
• <d-Color MF 552 plus/d-Color MF 452 plus>
Open fully the dual scan document feeder.
<d-Color MF 362 plus/d-Color MF 282 plus/d-
Color MF 222 plus>
Open fully original options if loaded.
• Do NOT place a document on the document
glass.
• Clean the document glass if dirty.
3. Press the Start key.
4. Make sure that "Result" is "OK."
Note:
If "Result" is "NG1" or "NG2", review the place and
direction of installation, or take measures to block
the light source (by covering it, etc.), then perform
installation checking again.
(If a fluorescent light or other bright light sources
exist right above the machine, the light source can
hinder installation checking and cause operation
errors in the Non-Image Area Erase Check. For
detailed information, see the service manual.)
5. Touch "OK."
6. Touch "Exit" on the Service Mode screen.
7. Turn OFF and ON the Main Power Switch.
Note:
When displayed the Service Mode screen, be sure
to turn off the main power after exiting the Service
Mode screen and wait for 10 seconds or more
before turning on.
Y115290-3
XXXII. Network setting
Make the TCP/IP address setting for the network.
Note:
Consult the network administrator for the setting
value to be entered and make settings as
required.
1. Select the function to be used as follows:
Menu → Utility → Administrator Settings → Enter
the Administrator Password → Network Settings
→ TCP/IP Settings → IPv4 Settings.
2. Touch "Manual Input" of IP Address Setting
Method and make the following settings.
IP Address: IP address of the controller
Subnet Mask: Subnet mask of the network, to
which the machine is connected
Default Gateway: IP address of the default gate-
way
3. Touch "OK."
4. Turn OFF and ON the Main Power Switch.
5. Select the function to be used as follows:
Menu → Utility → Administrator Setting → Enter
the Administrator Password → Network Settings
→ Forward → Detail Settings → PING Confirma-
tion, and make the operation check of TCP/IP.
Note:
After completing all the steps, take a sample
copy in color mode, and confirm the image. If
image troubles occur, first turn OFF and ON the
Main Power Switch, and then redo the steps
from E-11 "XII. Adjusting touch panel" to E-14
"XIX. List output."
A161IXC020DA
E-25
Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents