3.2
Adjustment When Replacing a Part
Adjustment is necessary when replacing any of the following parts.
3.2.1
Uploading/Downloading EEPROM data
When the controller printed circuit board is replaced, the contents of the old EEPROM shall be copied
to the new EEPROM on the new board to preserve customer settings. For the purpose, use the
Maintenance Utility.
A operation method of Maintenance Utility, please refer to Maintenance Utility Operating Specifications.
The maintenance utility is designed to be used only by field engineer and it should not be released to
the end-users.
42641101TH Rev.1
Part Replaced
Image Drum Cartridge
Reset the image drum counter
(refer to User's manual).
Main Control Board
EEPROM data Upload / Download
Adjustment