2.3.15 Fusing Unit

(1) Remove the upper cover (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face up stacker assy (see 2.3.8).
(4) Remove the lower base unit (see 2.3.4).
(5) Remove the stacker cover assy (see 2.3.12).
(6) Remove the connecting cable 1 of the heater and connecting cable 2 of the thermistor from the
hooks of the lower base.
(7) Remove four screws 3, lift and remove the fusing unit 4.
Caution: Fusing unit may be hot. Use care when handling.
When reinstalling or removing the fusing unit, tighten or loosen the screws while holding
Notes : 1.
the fusing unit assy 4 down with your hand (it is being pushed up by back up roller).
When reinstalling the screws 3, be sure to direct the screws into preexisting thread and
2.
avoid damaging the threads.
Do not apply excessive torque when tightening the screws 3.
3.
2
42641101TH Rev.1
3
1
3
4