2.3.19 Manual Feed Guide Assy

(1) Remove the upper cover assy (see 2.3.1).
(2) Open the manual feed guide assy 1, and release the engagement on both sides with the main unit
by carefully bending the manual feed guide assy 1.
When remounting, verify the proper the engagements as shown in the diagram.
Note :
42641101TH Rev.1
Oki Data CONFIDENTIAL
Put the post into the groove.
Put the post into the groove.
1
39 /