2.3.20 Sensor Plate (Paper Supply)
(1) Remove the upper cover assy (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face up stacker assy (see 2.3.8).
(4) Remove the lower base unit (see 2.3.4).
(5) Press the clamps of the sensor plate (paper supply) 1 to unlock the latch, and remove it from the
base plate 2.
42641101TH Rev.1
View A
1
View A
Oki Data CONFIDENTIAL
1
2
40 /