GAS CONVERSION KITS

Millivolt SIT Systems
Natural Gas To Propane Gas
Conversion Kits
Models
SDDV-35
SDDV-40
Millivolt SIT Systems
Propane to Natural Gas
Conversion Kits
Models
SDDV-35
SDDV-40
IMPORTANT
CANADA
The conversion shall be carried out
in accordance with the requirements
of the provincial authorities having
jurisdiction and in accordance with
the requirements of the CAN1-B149.1
And B149.2 Installation code.
Gas conversion kits are available to adapt your appliance from the use of one type of gas to
the use of another. These kits contain all the necessary components needed to complete the
task including labeling that must be affi xed to ensure safe operation.
Kit part numbers are listed here and the following steps detail the conversion procedure.
34
Electronic HONEYWELL Systems
Natural Gas To Propane Gas
Cat. No.
Models
85L62
SDDV-35
85L63
SDDV-40
Electronic HONEYWELL Systems
Propane Gas To Natural Gas
Models
Cat. No.
SDDV-35
85L69
SDDV-40
85L70
LE CANADA SEULEMENT
La conversion devra être effectuée
conformément aux recommanda-
tions des autorités provinciales
ayant juridiction et conformément
aux exigences du code d'installation
CAN1-B149.1 ET.2.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Conversion Kits
Cat. No.
85L76
85L77
Conversion Kits
Cat. No.
85L83
85L84
IMPORTANT
WARNING
This conversion kit shall be installed
by a qualifi ed service agency in
accordance with the manufacturer's
instructions and all applicable codes
and requirements of the authorized
having jurisdiction. If the information
in these instructions is not followed
exactly, a fi re, explosion or produc-
tion of carbon monoxide may result
causing property damage, personal
injury or loss of life. The installation
is not proper and complete until the
operation of the converted appliance
is checked as specifi ed in the owner
instructions supplied with the kit. The
qualifi ed service agency performing
this installation assumes responsibil-
ity for this conversion.
AVERTISSEMENT
Cet équipement de conversion sera
installé par une agence qualifi ée de
service conformément aux instruc-
tions du fabricant et toutes exigences
et codes applicables de l'autorisés
avoir la juridiction. Si l'information
dans cette instruction n'est pas suivie
exactement, un feu, explosion ou pro-
duction de protoxyde de carbone peut
résulter le dommages causer de pro-
priété, perte ou blessure personnelle
de vie. L'agence qualifi ée de service
est esponsable de l'installation propre
de cet équipment. L'installation
n'est pas propre et compléte jusqu'à
l'opération de l'appareil converti est
chéque suivant les critères établis
dans les instructions de propriétaire
provisionnées avec l'équipement.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sddv-40Sddv-35nmSddv-40nmSddv-35pmSddv-40pmSddv-35 series ... Show all

Table of Contents