Burner Air Shutter Adjustment Procedure
CAUTION
The air shutter door and nearby appliance surfaces are
hot. Exercise caution to avoid injury while adjusting
fl ame appearance.
Burner Air Shutter Adjustment Procedure
1. Locate adjustment rod and adjust air shutter to the standard setting
as shown in Figure 55 (adjustment rod is located in the lower control
compartment).To adjust the fl ame, move the adjustment rod back or
forward to increase or reduce the air shutter opening, respectively.
2. Light appliance (follow lighting procedure on lighting label in control
compartment or see homeowners manual).
3. Allow the burner to operate for at least 15 minutes while observing the
fl ame continuously to ensure that the proper fl ame appearance has
been achieved (see Figure 54). If the following conditions are present,
adjust accordingly.
• If fl ame appears weak or sooty, adjust air shutter, incrementally,
to a more open position until the proper fl ame appearance is
achieved.
• If fl ame stays lowered blue, adjust air shutter, incrementally,
to a more closed position until the proper fl ame appearance is
achieved.
4. Leave the control knob (off/pilot/on) in the ON position and the burner
OFF/ON switch OFF (& remote switches, if applicable).
5. When satisfi ed that the burner fl ame appearance is normal, re-install
the lower control compartment door then proceed to fi nish the instal-
lation.
Burner Flame Appearance Models -
SDDV-35 & SDDV-40 Series
Figure 54
Model
SDDV-35
SDDV-40
Figure 55 -

Step 11. HOOD INSTALLATION

(Refer to Figure 56)
All of these appliances must have hoods installed prior to operating.
Slide the hood into the slots on the lower edge of the cabinet top.
FINISHING REQUIREMENTS - Wall Details
Complete fi nished interior wall. To install the appliance facing fl ush
with the fi nished wall, position framework to accommodate the thick-
ness of the fi nished wall (Figure 56).
Combustible
Wall Framing
Combustible material may
touch the appliance top
Combustible materials
not allowed below this
point on the face of the
appliance.
Hood must be installed
as shown.
Figure 56
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Burner
Venturi
Tube
Air Shutter
Opening
Decrease
Increase
Air Shutter
Air Shutter
Opening
Opening
Air Shutter
Adjusting
Arm
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Natural Gas
1/8" (3.2 mm)
1/8" (3.2 mm)
Burner Air Shutter Adjustment
See Page 6 for Cold Climate Insulation
and Page 9 for Clearances
Combustible Finished
Wall Materials
Louvers
Air
Shutter
Door
Ref. Air shutter Patent:
U.S. Pat. 5,553,603
Orifice
Propane Gas
3/8" (9.5 mm)
3/8" (9.5 mm)
This Area Must
3"
Remain Clear of
(76 mm)
Combustible
Materials
1 in. Min.
(25 mm)
Top Spacers
Top of Appliance
Top of Door Frame
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sddv-40Sddv-35nmSddv-40nmSddv-35pmSddv-40pmSddv-35 series ... Show all

Table of Contents