Superior SLBV 35 Care And Operation Instructions Manual

Superior slbv 35; slbv 40 b-vent gas fireplaces
Hide thumbs Also See for SLBV 35:

Advertisement

Quick Links

P/N 506010-05 Rev. A 04/2013
This manual is one of a set of two supporting this product.
Refer to P/N 506009-05 for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-65.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
L'information de sûreté importante . . . . . . . . . . . . . . 3 - 4
[EN FRANÇAIS]
Apposition des mises en garde relatives à la sécurité d'utilisation . . . . 5
Información importante de seguridad . . . . . . . . . . . . . 3 - 4
[EN ESPAÑOL]
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
Wait...
INSTALLER: Leave this manual with the appliance.
DON'T
THROW
CONSUMER: Retain this manual for future reference.
IT AWAY!
INSTALLATEUR : Laissez cette notice avec l'appareil.
This manual contains
important operating
and safety
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
information.
WARNING / AVERTISSEMENT / AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
CARE AND OPERATION INSTRUC TIONS
B-Vent Gas Fireplaces
SLBV 35/40 Models
ETL Report No. 100017854
MODELS
Decorative Product: Not for use as a heating appliance.
NOTICE: Fireplace is not to be operated by a thermostat.
UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
MILLIVOLT:
SLBV-35NM
SLBV-40NM
SLBV-35PM
SLBV-40PM
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
ELECTRONIC:
SLBV35NE-2
SLBV40NE-2
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading

Summary of Contents for Superior SLBV 35

  • Page 1 CARE AND OPERATION INSTRUC TIONS B-Vent Gas Fireplaces P/N 506010-05 Rev. A 04/2013 SLBV 35/40 Models This manual is one of a set of two supporting this product. ETL Report No. 100017854 Refer to P/N 506009-05 for Installation Instructions. Ce manuel est disponible en francais, simplement MODELS en faire la demande.
  • Page 2: Table Of Contents

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® Thank you for your purchase. We appreciate your business! Safety and Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 3 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® [FRENCH] [SPANISH] La sécurité et Seguridad y votre foyer su chimenea Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES !
  • Page 4: Important Safety Information

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué...
  • Page 5: Attaching The Safety-In-Operation Warnings

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD à LA SÉCURITÉ D’UTILISATION EN OPERACIóN...
  • Page 6: Appliance Installation, Service, And Maintenance Notices

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® APPLIANCE INSTALLATION, SERVICE, APPLIANCE OPERATION NOTICES WARRANTY INFORMATION AND MAINTENANCE NOTICES Your gas appliance is covered by a limited Do not operate appliance with the glass 20-year warranty.
  • Page 7 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® These appliances comply with National Safety Manifold Gas Supply Pressure Burner Orifice Sizes Standards and are tested and listed by ETL/ (all models) Elevation 0-4500 feet ( 0-1372 meters) Intertek.
  • Page 8: Operation/Care Of Your Appliance

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® OPERATION AND CARE OF YOUR APPLIANCE GAS CONTROLS / CONTROL COMPARTMENT ACCESS WARNING Fireplace gas controls are located in the lower control compartment under the firebox (see Young children should be carefully supervised when they are in the Figure 1).
  • Page 9: Appliance Controls

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® Appliance Controls ON/OFF Control IMPORTANT: Do NOT assume your fire- place has a complete supplemental com- Available ON/OFF control options for both Operation of millivolt and electronic gas...
  • Page 10: Maintenance Instructions

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® MAINTENANCE INSTRUCTIONS Order Replacement Logs Note: Clean glass after first two weeks of operation (after burn-in period is over) and If the logs become damaged and need to be...
  • Page 11: Removing And Installing The Glass Enclosure Panel

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® REMOVING AND INSTALLING WARNING: DO NOT abuse glass enclo- 5. If the hood was uninstalled, reinstall the required hood. Note the location of the sure panel by striking or slamming shut.
  • Page 12: Installing Volcanic Stone, Glowing Embers (Rockwool), And Logs

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® INSTALLING VOLCANIC Separate the Embers (rockwool) into pieces WARNING about the size of a quarter (Figure 8). Keep STONE, GLOWING EMBERS the pieces fluffed up, not matted. Distribute •...
  • Page 13: Slbv-35 Log Placement

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® SLBV-35 LOG PLACEMENT INSTRUCTIONS NOTE: Left Rear Log Right Rear Log • Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. • Install volcanic stone and glowing embers BEFORE installing logs.
  • Page 14: Slbv-40 Log Placement

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® SLBV-40 LOG PLACEMENT INSTRUCTIONS NOTE: • Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. Ember Chunk • Install volcanic stone and glowing embers BEFORE installing logs.
  • Page 15: Burner Air Shutter Adjustments

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® BURNER AIR SHUTTER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame.
  • Page 16: Burner Air Shutter Adjustment Procedure

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® Burner Air Shutter Adjustment APPLIANCE CHECKOUT 3. Allow the burner to operate for at least 15 minutes while observing the flame continu- Procedure ously to ensure that the proper flame ap-...
  • Page 17: Spillage Test

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® SPILLAGE TEST Lintel Screw Hole After appliance installation, perform this spillage in Cabinet Top test to verify proper venting conditions: 1 - Place unit in its normally-operated condi- tion, that is, with the glass enclosure panel in place.
  • Page 18: Ordering Replacement Parts

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® ORDERING REPLACEMENT PRODUCT REFERENCE PARTS INFORMATION A complete parts list is found at the end of We recommend that you record the important reference information about your fireplace in the this manual.
  • Page 19 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® JUNCTION BOX AC/DC 120V AC POWER ELECTRONIC PILOT ASSEMBLY ADAPTOR IGNITER ROD HOOD NEUTRAL FLAME SENSOR GROUND PILOT PROFLAME VALVE PILOT TUBE SENSOR CABLE SPARK WIRE CABLE...
  • Page 20: Accessory Components

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® ACCESSORY COMPONENTS Product Reference Information Cat. Ship. Ship. Model Volume H8105 SLBV-35NM H8106 SLBV-35PM 100 lb. 11.35 cu. ft. H8107 SLBV-35NE H8108 SLBV-40NM Unit-Mountable ON/OFF Rocker Switch Kit...
  • Page 21 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® Style View™ Doors ACCESSORY COMPONENTS (continued) Style View doors come in two styles. They are easy to install onto the standard glass door frame. Includes heavy-duty magnetic door latches and functional twin-pane doors.
  • Page 22: Lighting Instructions - Millivolt

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® LIGHTING INSTRUCTIONS - MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 23 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® INSTRUCTIONS D’ALLUMAGE - VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 24: Lighting Instructions - Electronic

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® LIGHTING INSTRUCTIONS - ELECTRONIC FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 25 SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® INSTRUCTIONS D’ALLUMAGE - ELECTRONIC POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 26: Maintenance Schedule

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® MAINTENANCE SCHEDULE Annually (before burning season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspect/Clean Burner, Logs, Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for and Controls leaks.
  • Page 27: Troubleshooting Guide - Millivolt

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® TROUBLESHOOTING GUIDE: MILLIVOLT GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, if applicable), is in the “ON”...
  • Page 28: Troubleshooting Guide - Electronic

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® TROUBLESHOOTING GUIDE: ELECTRONIC GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, if applicable), is in the “ON”...
  • Page 29: Replacement Parts List

    SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® REPLACEMENT PARTS LIST SLBV-35 SLBV-40 Gas Controls - SIT Electronic Item Description Part No. Qty. Part No. Qty. Item Description Part No. Qty. Hood H7266 H7267...
  • Page 30: Replacement Parts

    Dexen Gas Controls SUPERIOR B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS ® REPLACEMENT PARTS SIT Electronic Gas Controls SIT Gas SIT Millivolt Controls Gas Controls 33 3 (Ref.) NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

This manual is also suitable for:

Slbv 40