5 - Replace the switch.
6 - Reinstall the switch/bracket assembly.
7 - Reinstall the scoop and lintel.
8 - Reinstall the glass enclosure panel.
9 - Reinstall the bottom control compartment
access panel and the top louver panel.
10 - The appliance should then relight and
remain lit. If this does not occur, check
unit for a blocked fl ue condition.
Blocked Flue Safety Limit Location - See
Figures 32, 33 & 34. Inside View of Firebox
- Top/Right Side Intersection
Figure 32
Lintel Securing Screw
Firebox
f i r e - p a r t s . c o m
Hole in Cabinet Top
Top
Scoop
Scoop Securing Screws
Figure 33
Lintel Securing Screw
Firebox
Hole in Cabinet Top
Top
Spill Switch (limit disc)
Bracket Securing Screws
Spill Switch (limit disc)
View Without Scoop
Figure 34

Step 14. HOOD INSTALLATION

(Refer to Figure 35)
All of these appliances must have a hood
installed prior to operating.
Slide the hood into the slots on the lower edge
of the cabinet top.

FINISHING REQUIREMENTS -

Wall Details
Complete fi nished interior wall. To install the
appliance facing fl ush with the fi nished wall,
position framework to accommodate the thick-
ness of the fi nished wall (Figure 35).
See Page 5 for Cold Climate Insulation
and Page 6 for Clearances
Combustible
Wall
Framing
Combustible
Finished Wall
Materials
Combustible
material may
touch the appli-
ance top
Wire
Terminals
Cabinet
Corner
Back of Spill
Switch (high
Hood must
limit disc)
be installed
as shown.
Door
Frame

INSTALLATION ACCESSORIES

The following accessory items are available
for use in the installation of these appliances.
See Homeowners Manual for a complete list of
accessories and more detailed information on
the following installation accessories:
Outside Combustion Air Kits
Cat. No.
Model No.
81L87
FOAK-4
81L88
FOAK-4LD
Cat. No.
Model No.
85L87
FWSK
Cat. No.
Model No.
80L41
Remote Control Kit, Standard
Cat. No.
Model No.
H0249
Cat.
Model No.
No.
80L84
FBK-100
80L85
FBK-200
80L86
FBK-250
94L89
FBK-100-36
94L90
FBK-200-36
H0543
FBK-250-36
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Finishing Requirements
1 in. Min.
(25 mm)
Top
Spacers
Top of Appliance
Louvers
Top of Door
Frame
Figure 35
Description
Combustion Air Kit (w/duct)
Combustion Air Kit (w/o duct)
White Wall Switch Kit
Description
OFF/ON Wall Switch Kit
Rocker Switch Kit
Description
FRS
Rocker Switch Kit
Description
RCL
Remote Control System
Forced Air Blower Kits
Description
Blower, Standard
(single speed)
Blower, Variable Speed
(w/wall-mounted switch)
Blower, Variable Speed
(w/unit-mounted switch)
Blower, Standard, 36 Pack
Blower - Variable, 36 Pack
Blower - Variable, 36 Pack

GAS CONVERSION KITS

Millivolt SIT Systems
Natural Gas To Propane Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Millivolt SIT Systems
Propane to Natural Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Millivolt HONEYWELL Systems
Natural Gas To Propane Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Millivolt HONEYWELL Systems
Propane Gas To Natural Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Electronic HONEYWELL Systems
Natural Gas To Propane Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Electronic HONEYWELL Systems
Propane Gas To Natural Gas
Conversion Kits
Models
SSBV-3530
SSBV-4035
Cat. No.
85L59
85L60
Cat. No.
85L66
85L67
Cat. No.
11M37
11M38
Cat. No.
11M34
11M35
Cat. No.
85L73
85L74
Cat. No.
85L80
85L81
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssbv-4035cnmSsbv-4035cneSsbv-3530cne

Table of Contents