E1 Stall/ E1 Range - True Fitness TREADMILL 2011 Service Manual

Table of Contents

Advertisement

If the value at zero or -3% incline is outside the
acceptable range (see pg. 11) of the correct digital value,
the machine will give an elevation error (either E1 Stall
or E1 Range depending on model).
On units with an external limit switch, the digital value
can be adjusted by disconnecting the elevation motor
from the incline rack and manually turning the linear
shaft of the incline motor until it reads the correct digital
value at 0% or -3%.
On treadmills with internal limit switches in the incline
motor the ideal zero will be set when the internal switch
activates.
A value reading 255 or 0 often indicates over travel of
the potentiometer or a wire disconnect between the
potentiometer and the upper control panel.
Proprietary & Confidential
Proprietary & Confidential
TRUE Fitness Technology, Inc.
TRUE Fitness Technology, Inc.

E1 STALL/ E1 RANGE

Tread Service Manual - July 2011
16