Installation Requirements; Odor During Operation; High Elevations - Vermont Castings UVL18RN Installation And Operation Instructions Manual

Vent-free gas log sets
Table of Contents

Advertisement

The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the
fireplace does not meet these minimums.
Logset
Gas
18" UVL18RN
18" UVL18MN
24" UVL24RN
Natural
24" UVL24MN
30" UVL30RN
30" UVL30MN
18" UVL18RP
18" UVL18MP
24" UVL24RP
Propane
24" UVL24MP
30" UVL30RP
30" UVL30MP
A. Front Width
C. Depth
Fig. 1 Minimum fireplace dimensions.
Pressure Test Points
UVL-R Series: The gas control is equipped with a
captured screw-type pressure test point, therefore it
is not necessary to provide a 1/8" test point
upstream of the control.
UVL-M Series: The gas valve control is equipped
with a captured screw type inlet and manifold
pressure test point on the right side of the valve.

Odor During Operation

Neither natural gas nor propane gas give off an odor
when burned. The nature of a vent free combustion
system, however, is such that odors may
UVL Series

Installation Requirements

Min. Fireplace Dimensions
A
B
C
Front
Rear
Overall
Width
Width
Depth
30"
17"
15"
33"
20"
15"
36"
25"
15"
30"
17"
15"
33"
20"
15"
36"
25"
15"
D
B
C
A
B. Rear Width
D. Height
FD370-2
D
Inlet Supply
Overall
Pressure (w.c.)
Height
Min.
Max.
18"
5.5"
14.0"
18"
5.5"
14.0"
18"
5.5"
14.0"
18"
11.0"
14.0"
18"
11.0"
14.0"
18"
11.0"
14.0"
occasionally be produced during heater operation
when impurities exist in the immediate area.
Cleaning solutions, paint, solvents, cigarette smoke,
candles, adhesives, new carpet or textiles, etc., all
can create fumes. These fumes may mix with
combustion air and can create odor. Such odors will
disappear over time, however, the condition can be
alleviated by opening a window or otherwise
providing additional ventilation to the area.

High Elevations

Input ratings are shown in BTU per hour and
are certified without deration from elevations
up to 4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370m) if dirt, dust, lint and/or
cobwebs are allowed to accumulate on burner
and/or ODS pilot. Monthly inspection and
cleaning is recommended for altitudes above
4,500 feet (1,370m)
For elevations above 4,500 feet (1,370m) in
USA, installations must be in accordance with
the current ANSI Z223.1 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or
local authorities having jurisdiction for
installations at elevations above 4,500 feet
(1,370m)
Manifold
Min. Input
Max. Input
Pressure
BTU/hr
17,000
3.5"
15,000
24,500
3.5"
18,000
25,000
3.5"
28,500
11.0"
18,000
10.0"
17,000
11.0"
26,000
10.0"
18,000
11.0"
29,500
10.0"
29,000
BTU/hr
24,000
24,000
35,000
35,000
39,000
39,000
24,000
24,000
35,000
35,000
39,000
39,000
3