Chapter 2
Installing the Access Point
Figure 2-38
1
DC power connector with liquid-tight adapter 2
Loosen the round end of the liquid-tight adapter by turning counterclockwise, but do not remove (see
Step 4
Figure
Figure 2-39
1
Thread end
Note
Insert a bare end of the DC power cable into the rounded end of the liquid-tight adapter (see
Step 5
Figure
Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 inch
Step 6
(9.5 mm) from each wire.
Step 7
Insert each wire into the two-position terminal strip (supplied), and tighten each wire using a 0.1 inch
(0.25 cm) flat screw driver (see
OL-24247-01
Location of the DC Power Liquid-Tight Adapter
2-39).
Liquid-Tight Adapter
The liquid-tight adapter accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).
2-39), and pull approximately 6 inches of cable through the adapter.
Figure
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
1
2
Ground lug screw holes
2
Round end
2-40).
Powering the Access Point
2-55