Installing the Access Point
Use four customer-supplied screws and optional screw anchors to attach the mounting plate to the
Step 2
mounting surface.
Note
When installing the 1552C access point using the pole mount kit, the grounding lug and cable must be
Tip
attached to the access point before attaching the access point to the mounting bracket.
When installing the 1552C access point in this configuration, you can use only one hole in the grounding
Tip
block (see
Step 3
Attach the grounding lug and cable to the access point. Refer to
on page
Figure 2-20
1
Unused
2
Phillips head M4 x10mm screw (supplied
with pole mount kit)
Step 4
Screw a M8 x16 bolt in the top support bolt hole on each side the access point (see
screw the bolt all the way in; leave approximately a 0.25 inch (0.635 cm) space.
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-32
If necessary, use suitable screw anchors and an exterior-grade plywood backboard to mount the
access point to stucco, cement, or drywall.
Figure
2-20).
2-40.
Attaching Grounding Lug to Grounding Point
Chapter 2
"Grounding the Access Point" section
1
2
3
3
Grounding lug
Installing the Access Point
Figure
2-21). Do not
OL-24247-01