Theory of Operation Ver. 1.0 Mar. 2005
24.2 Parts Operated When the Power Switch and Auxiliary Power
Button are turned ON
24.2.1
Parts operated when the Power Switch and Auxiliary Power Button are
turned ON
• When the Auxiliary Power Button is turned ON, the Control Board detects it and sends a
control signal to the DC Power Supply.
• The DC Power Supply then supplies 3.3V DC, 5V DC, 15V DC, and 24V DC to all PWBs
and options. It also turns ON the relays in the PWBs, supplying AC power to each of the
heater lamps.
SW1
24VDC
24VDC
PU1
5VDC
24VDC
15VDC
PWB-C
5VDC
24VDC
5VDC
24VDC
5VDC
24VDC
24VDC
12VDC
5VDC
5VDC
3.3VDC
RY
Auxiliary Power Button
ADF
PWB-IC
5VDC
24VDC
5VDC
PWB-MC
5VDC
5VDC
5VDC
PWB-SIF
5VDC
12VDC
24VDC
PWB-MFPC
PWB-LED
H1,H2,H3
24. Other control
UN201
PWB-A
FS-603/FS-507
(OPTION)
AD-501
(OPTION)
PC-202
PC-102
(OPTION)
PC-402
(OPTION)
DUPLEX
4037T2C582AA