22. Image stabilization control
22.4 Operation flow
Mode 1
IDC intensity
control
Max. density
control 1
Max. density
control 2
Gamma correction
control
Registration
control
* The ATVC control is performed simultaneously with the IDC intensity control.
* Max. density control 1: A pattern is produced on the Transfer Belt using the Vdc data of
Max. density control 2: A pattern is produced on the Transfer Belt using the Vdc data of
102
Mode 2
Mode 3
IDC intensity
IDC intensity
control
control
Max. density
Max. density
control 2
control 2
Gamma correction
Gamma correction
control
control
Registration
control
four different levels as reference for each color and the adequate
Vdc is thereby set.
four different levels with reference to the Vdc data used last and
the adequate Vdc is thereby set.
Theory of Operation Ver. 1.0 Mar. 2005
Mode 4
IDC intensity
control
Max. density
control 2
Gamma correction
Gamma correction
control
control
Test pattern
output
Mode 5
4037T2E607AA