Belt Replacement - Windsor Clipper CLP12 Operating Instructions Manual

Carpet extractor
Hide thumbs Also See for Clipper CLP12:
Table of Contents

Advertisement

MAINTENANCE
!
WARNING:
PERFORM THE FOLLOWING REPAIRS.
VACUUM MOTOR REPLACEMENT
1. Turn off all switches and unplug machine.
2. Remove recovery tank.
3. Remove the (2) screws that fasten the solution tank
to the frame, and tilt tank back to expose the inside
of the frame.
4. Locate the vacuum motor wires and disconnect at
the connector. Close the solution tank.
5. Remove the (6) screws holding the vacuum motor
cover (p/n 27809) to the solution tank.
6. Remove the vacuum motor.
7. Reverse process to install vacuum motor.

BELT REPLACEMENT

1. Turn off all switches and unplug the machine.
2. Remove recovery tank.
3. Remove the (2) screws that fasten the solution tank
to the frame, and tilt tank back to expose the inside
of the frame.
4. Remove solution hoses from fittings in pump.
5. Remove the (2) screws that fasten the pump to the
frame.
6. Reverse process to install pump.
17
ONLY QUALIFIED
MAINTENANCE
PERSONNEL ARE TO
62759
05016
CLIPPER 98630 10/19/02
Vac Motor Carbon Brushes Replacement
Carbon Brushes
115V
Note: When replacing carbon vac motor brushes
loosen wire terminal BEFORE removing screws on
bracket.
If armature commutator is not concentric, extremely
pitted, or grooved the motor will need to be replaced
or sent to a qualified service center to restore vac
performance.
Wire Terminal
Important:
These brushes wear quicker
as the length shortens due to
increased heat.
Spring inside brush
housing will damage motor
if brushes are
allowed to wear away
completely.
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less
than 3/8" long.
End Cap
WARNING: The green
ground wire must be
attached for safe
operation.
See wiring diagram.
Wire
Terminal
Note:
Place
stop in
groove.
3/8