SERVICE MANUAL
PROBLEM
Mobility
device
judders in
drive mode
Batteries
not being
charged
Mobility
device
runs too
slowly
Electrical
adjustment
motor does
not react
28
OTHER
POSSIBLE
SYMPTOMS
CAUSE
None
Batteries
defective
(unstable
voltage)
Drive motor(s)
defective
None
Batteries
defective
LEDs blinking
Charging unit
on charging
defective
unit
None
Remote
defective
Batteries
defective
Remote shows
Lighting /
a blinking "E",
actuator
status diode on
module
lighting/actuato
defective
r module does
not go out even
if remote is
switched off or
disconnected.
None
Cable
disconnected
or damaged
Electrical
adjusting motor
defective
Remote
defective
SOLUTION
Documentation
Replace batteries
See chapter 7.7.
Replace motor(s)
See chapter 7.2.
Replace carbon
See chapter 7.2.4.
brushes
Replace batteries
See chapter 7.7.
Replace charging
See charging unit
unit
operating manual
Replace remote
See chapter 7.10.
Replace batteries
See chapter 7.7.
Replace lighting
See chapter 7.3.
/ actuator
module
Safeguard cable
See chapter 7.9.
connection,
replace cable if
necessary
Check adjusting
See chapter 7.17.
motor
Replace remote
See chapter 7.10.
®
Invacare
- Bora