BX620 S4 Server Blade
This Server Blade contains a CPU, memory, and a hard disk in the unit (42 × 476 × 286mm).
Storage Blade
This is a blade type storage subsystem in which up to 5 hard disks can be installed.
Install the Storage Blade in the chassis' Server Blade slot, and connect to the SAS RAID Ctrl that is
installed in the Server Blade to the left side of the Storage Blade using an exclusive cable.
Network Blade
This is an option that can be connected to LAN port and Fibre Channel devices.
Refer to each Network Blade manual for details about Network Blades that are not described in this
manual.
• Switch Blade
This is a LAN switching hub that supports a Gigabit LAN.
• Fibre Channel Switch Blade
This is a Switch Blade that enables fibre channel connection. The Switch Blade supports a Brocade
Fabric Operating System (Fabric OS) and is compatible with all SilkWorm products.
• GbE Pass-Thru Blade
The GbE Pass-Thru Blade is used to connect the internal LAN ports (including a LAN Expansion
Board) in a Server Blade to the external LAN ports at a ratio of 1:1.
• FC Pass-Thru Blade
FC Pass-Thru Blade is used to connect between the ports of the Fibre Channel Expansion Board
(optional) that is installed in the Server Blade and the external Fibre Channel ports at a ratio of 1:1.
Management Blade (monitoring device)
This blade is used to monitor the power supply, fan, and temperature in each blade and the Chassis.
It is equipped with a dedicated CPU, LAN, and serial ports. This blade is independent of the Server
Blade, ensuring stable system operation.
The Management Blade also enables you to remotely control and monitor each blade from a
management terminal via a LAN or serial port.

High reliability

Redundant function
This server enables a redundant configuration for fan, power supply unit (optional), and Management
Blade.
The Management Blade supports the standard redundant configuration in which one unit manages the
entire system in the master mode and another one is on standby in the slave mode. In this configuration,
if the master Management Blade causes a failure, the slave blade takes over management without
interrupting system operations.