New Buck Corporation COMBO COAL & WOOD STOVE Owner's Manual page 21

For burning bituminous / anthracite coal or hard, seasoned natural wood
Table of Contents

Advertisement

D. REAR EXIT TO VERTICAL CEILING EXIT USING
(6" Single Wall pipe minimum 24 ga. blued or black pipe with Elbow) or
(6" DVL Close Clearance pipe with Elbow)
Minimum Clearance to Combustibles.
A B C D E F G H I
J
FLOOR PROTECTOR: MINIMUM R-VALUE OF 1.8.
19" 30" 22" NA NA 16" 8" 8" 10" 16"
F
B
G
Clearances to Combustibles and also Masonry Materials.
I
B
(6" Single Wall pipe minimum 24 ga. blued or black pipe)
G
H
A B C D E F G H I
J
J
A
F
E
16" 22" 14" NA NA 16" 8" 8" 10" 16"
D
FRONT OF STOVE
A
Clearances to Combustibles and also Masonry Materials.
Figure 16
(6" DVL Close Clearance pipe)
NOTE: All clearances are to combustibles with minimum floor protector.
NOTE: Floor protector must extend length of horizontal flue pipe to wall.
LISTED 2100° UL 103 HT TYPE
CHIMNEY ASSEMBLY REFER
TO MANUFACTURERS
INSTALLATION INSTRUCTIONS
C
6" Single
Wall Pipe
Figure 17
Page 19