  • Page 1 METROLOGIC INSTRUMENTS, INC. IS4320 ScanGlove Programming Guide MLPN 2405 Printed in USA April 1998...
  • Page 2 Copyright ® © 1998 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    Table of Contents Programming the Scanner ........1 Enter Program Mode .
  • Page 4 UPC/EAN Code ..........22 UPC-A Options .
  • Page 5: Programming The Scanner

    Programming the Scanner The IS4320 is shipped from the factory programmed to a set of default parameters. Defaults are noted in the following pages by double asterisks next to the bar code labels. Modifications to the default program to match the host system are made using bar codes contained in this manual.
  • Page 6: Enter Program Mode

    Enter/Exit Program Mode Enter Program Mode When this option is selected, enter **Ability to Enter Program Mode After Any Scan programming by scanning the ENTER/EXIT PROGRAM MODE bar code after power up or during normal scanning operation. When this option is selected, the scanner Enter Program Mode Only on First Scan will only enter program mode after power-...
  • Page 7: Laser Activation Range

    Recall Defaults Laser Activation Range Short Range Activation When this option is selected, the IR sensor guarantees to activate when the Out of the Stand scanning window is positioned three inches from the object. Short Range Activation When this option is selected, the IR In the Stand sensor guarantees to activate when an object is presented three inches from...
  • Page 8: Laser Operation

    Custom Scan This option is available for special applications. Do not scan the CUSTOM SCAN bar code unless instructed by a Metrologic representative.
  • Page 9: Same Symbol Re-Scan

    Recall Defaults Same Symbol Re-Scan The scanner is programmed with a same symbol Short Same timeout. For SHORT SAME SYMBOL RE-SCAN, Symbol Re-Scan the time delay is ½ second, while the LONG SAME SYMBOL RE-SCAN delay is 1 second. These numbers represent the amount of time that a bar code must be out of the scan field before it can be scanned again.
  • Page 10: Beeper Tones

    Enter/Exit Program Mode Beeper Tones Program the scanner to emit a certain tone. Alternate Tone 1 ....... . . Low Tone Alternate Tone 2 .
  • Page 11: Audible Indicators For Communication Timeouts

    Recall Defaults Audible Indicators for Communication Timeouts Two Second Timeout When this option is selected, the scanner will timeout if it does not transmit its data to the host after two seconds during communica- tion. This is only valid in modes where some type of hand-shaking is involved.
  • Page 12: Rs-232 Interface

    Enter/Exit Program Mode RS-232 Interface ** Enable RS-232 Interface RS-232 Parameter - Baud Rate A baud rate is a unit that measures the speed with which information transfers. The baud rate of the scanner must equal the baud rate of the host device. The available baud rates range from 150 to 19200.
  • Page 13 Recall Defaults 2400 Baud Rate 4800 Baud Rate ** 9600 Baud Rate 19200 Baud Rate...
  • Page 14: Rs-232 Parameter - Parity

    Enter/Exit Program Mode RS-232 Parameter - Parity Parity is an additional digit that makes the number of bits in the ASCII code odd or even. The scanner’s parity must match the host’s parity. **Space Parity Select this option to make the parity bit always 0. Select this option to make the additional parity bit Even Parity either a 0 or 1 to guarantee an even number of bits.
  • Page 15: Rs-232 Parameter - Data Bits

    Recall Defaults RS-232 Parameter - Data Bits RS-232 serial communication requires ASCII data to 8 Data Bits transmit in either 7 or 8 data bits. In addition, one parity bit will transmit. If necessary, scan the appro-priate bar code that matches your host device’s requirements. ** 7 Data Bits...
  • Page 16: Rs-232 Parameter - Hardware Handshaking

    Enter/Exit Program Mode RS-232 Parameter - Hardware Handshaking Enable RTS/CTS To prevent scanned information from being lost during transmission, your host device may require an RTS/ CTS signal. When RTS/CTS (Ready To Send/Clear To Send) enables, the scanner will output an RTS signal and wait for a CTS signal before any data transmits.
  • Page 17: Rs-232 Parameter - Software Handshaking

    Recall Defaults RS-232 Parameter - Software Handshaking For control of the data transmission process, use the following parameters instead of or in addition to the RTS/CTS hardware handshaking option. ACK/NAK When this option is enabled,the Enable ACK/NAK scanner will not scan again unless after transmission of a bar code it receives an ACK (ASCII 06H).
  • Page 18: Rs-232 Parameter - Intercharacter Delay

    Enter/Exit Program Mode RS-232 Parameter - Intercharacter Delay The time specified with an intercharacter delay bar code represents the interim of time between transmission of characters. Some host systems require this delay when receiving transmissions. If necessary, scan the appropriate bar code.
  • Page 19: Rs-232 Parameter - Scanning Control (Dtr Signal)

    Recall Defaults RS-232 Parameter - Scanning Control (DTR Signal) When the DTR (Data Terminal Ready) input is Enable DTR Input enabled, the scanner will not transmit unless an active (+12V) DTR signal is present on the scanner’s DTR input pin. You can disable the scanner by making DTR inactive (-12V) at the DTR input pin.
  • Page 20 Enter/Exit Program Mode When this option is on, the scanner will transmit a Line Feed after each bar code. LF On LF Off STX Prefix When this option is on, the scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. STX Prefix On ** STX Prefix Off...
  • Page 21 Recall Defaults ETX Suffix When this option is on, the scanner will transmit an End of TeXt (ASCII 03H) after each bar code. ETX Suffix On ** ETX Suffix Off Tab Prefix When this option is on, the scanner will transmit a TAB (ASCII 09H) before each bar code.
  • Page 22: Rs-232 Parameter - Upc/Ean Identifiers

    Enter/Exit Program Mode RS-232 Parameter - UPC/EAN Identifiers Prefix ID When this option is on, the scanner Prefix ID On will transmit a prefix before any UPC/ EAN bar code. The prefixes are A (UPC- A), E0 (UPC-E), F (EAN-13), and FF (EAN-8).
  • Page 23: Light Pen Options

    Recall Defaults Light Pen Options If the scanner is being used in place of a light pen, Enable Light scan the ENABLE LIGHT PEN INTERFACE Pen Interface bar code. When this interface, is enabled the scanner can output a bar or space as the high signal.
  • Page 24: Code Type Selections

    Enter/Exit Program Mode Code Type Selections Use the following bar codes to program the scanner to read different types of bar codes. This will enable the default settings for all of the bar code types. To improve reliability, disable the code types that will not be used. This will not decrease the amount of time it takes for the scanner to scan a bar code.
  • Page 25 Recall Defaults ** Enable Codabar Disable Codabar ** Enable Code 128 Disable Code 128 ** Enable Code 93 Disable Code 93 ** Enable Interleaved 2 of 5 Disable Interleaved 2 of 5...
  • Page 26: Minimum Code Length For All Code Types

    Enter/Exit Program Mode Minimum Code Length for All Code Types The minimum number of characters can be Minimum 1 Character specified in the bar code that will be scanned by scanning one of the follow ing bar codes. For example, when the minimum is 3,the scanner will not scan bar codes that have less than 3 characters.
  • Page 27: Upc-A Options

    UPC-A Options **Transmit UPC-A Number Sys When this option is selected , the scanner will transmit the UPC-A number system character. Metrologic strongly discourages the disabling of this feature because duplicate numbers may result in the database when the scanner is programmed not to transmit the UPC-A number system character.
  • Page 28: Upc-E Options

    Enter/Exit Program Mode UPC-E Options Expand UPC-E When this option is selected, the scanner will expand UPC-E to the 12 digit equivalent UPC-A. ** Do Not Expand UPC-E UPC-E Check Digit On When this option is on, the scanner will transmit the UPC-E check digit.
  • Page 29: Supplemental Upc Options

    Recall Defaults Supplemental UPC Options When this option is enabled, the scanner will Enable 2 Digit Supps scan 2 digit supplementals. ** Disable 2 Digit Supps Enable 5 Digit Supps When this option is enabled, the scanner will scan 5 digit supplementals. ** Disable 5 Digit Supps When this option is selected , the scanner will Convert EAN-8 to EAN-13...
  • Page 30: Code 39

    Enter/Exit Program Mode Code 39 **Enable Code 39 When this option is enabled, the scanner will scan Code 39 bar codes. Disable Code 39 Enable Mod 43 Check Digit When this option this enabled, the scanner will only scan Code 39 bar codes that have a Modulo 43 check digit.
  • Page 31: Codabar

    Recall Defaults Enable Full ASCII Code 39 When this option is enabled, the scanner will scan full ASCII Code 39 bar codes. ** Disable Full ASCII Code 39 Codabar When this option is enabled, the scanner will **Enable Codabar scan Codabar bar codes. Disable Codabar TransmitStart/Stop When this option is selected, the scanner will...
  • Page 32: Interleaved 2 Of 5 (Itf)

    Enter/Exit Program Mode Interleaved 2 of 5 (ITF) ** Enable ITF When this option is enabled, the scanner will scan Interleaved 2 of 5 (ITF) bar codes. Disable ITF Enable ITF Check Digit When these options are enabled, the scanner will scan ITF bar codes that have a Modulo 10 check digit.
  • Page 33: Interleaved 2 Of 5 (Itf) Symbol Lengths

    Recall Defaults Interleaved 2 of 5 (ITF) Symbol Lengths Specify the number of ITF digits in the bar codes that will be scanned by scanning the appropriate bar codes. Specify a maximum of two bar code lengths. If all of the bar codes that will scan are variable lengths, program the scanner to VARIABLE LENGTH.
  • Page 34 Enter/Exit Program Mode 14 Digits 16 Digits 18 Digits 20 Digits 22 Digits 24 Digits 26 Digits 28 Digits 30 Digits...
  • Page 35 Recall Defaults 32 Digits 34 Digits 36 Digits 38 Digits 40 Digits 42 Digits 44 Digits 46 Digits...
  • Page 36: Msi - Plessey Check Digit

    Enter/Exit Program Mode 48 Digits 50 Digits MSI - Plessey Check Digit Enable MSI - Plessey When this option is enabled, the scanner will scan Plessey bar codes. ** Disable MSI - Plessey **Enable MSI - Plessey Test of Check Digit When this option is enabled, the scanner will check the Plessey bar code for a proper check digit.
  • Page 37 Recall Defaults **Transmit Plessey Check Digits When this option is selected, the scanner will transmit Plessey’s check digit(s) character. This option works with the Plessey Mod 10 and/or Plessey Mod 10/10 features. Enable this option and one or both of the Plessey Mod options in order for this feature to work.
  • Page 38: Test Modes

    When this option is enabled, the scanner Scannability will enter the scannability test mode. Do not enable this feature unless a Metrologic representative instructs to do so. When this option is selected, the scanner Normal Scan will exit from the scannability or scan count test modes.
  • Page 39: Special Features

    Recall Defaults Special Features The special features options are for special applications. Do not enable any of the special features options unless instructed by a Metrologic representative. ** Disable Sanyo 635 ECR Protocol Enable Sanyo 635 ECR Protocol Enable Post Software ID Characters ** Disable Post Software ID Characters Enable “NEWCODE”...
  • Page 40 Enable this option when using the Caps Enable Caps Lock Mode Lock on the keyboard. Once enabled, (For the MI951 external wedge) Metrologic’s MS951 (RS-232) hand- held scanner will simulate Caps Lock keyboard input when used with Metrologic’s MI951 external keyboard wedge.
  • Page 41: Reserved Codes

    Recall Defaults Reserved Codes Metrologic has reserved the codes on the following pages for features that will be added at a later date. Do not assign a function for any of the reserved codes.
  • Page 42 Enter/Exit Program Mode...
  • Page 43 Recall Defaults...
  • Page 44 Enter/Exit Program Mode...
  • Page 45 Recall Defaults...
  • Page 46: Disclaimer

    Il leur est également réservé le droit de procéder à des modifications de cette brochure sans avoir à en avertir qui que ce soit. Metrologic se réserve en outre le droit de procéder à des modifications du produit qui y est décrit.
  • Page 47: Index

    Index ACK/NAK 13 check digit 25 Airline 2 of 5 33 EAN-8 to EAN-13 25 Asia ETX Suffix 17 Europe ii Baud Rate 8, 9 Beep French Wyse 120V PC Term 36 after transmit 7 before transmit 7 Beeper Tones 6 Germany (GmbH) Bookland 25 Brasil...
  • Page 48 Parity 10 Timeout Plessey 32 razz beep 7 mod 10 check digit 32 three beep 7 mod 10/10 check digit two second 7 test of check digit 32 UPC 20, 22 transmit check digits 33 UPC-A Poll Light Pen 5 Volts 19 check digit 23 Post Software ID Characters 35 convert to EAN-13 23...