Top Vent Configuration with Vertical Termination
•
The termination must fall
within the shaded area shown
in the chart. Use the indicated
restrictor and diffuser
positions.
•
Up to four elbows (45° or 90°)
may be used.
•
Only one horizontal elbow
may be used.
•
May use 8" or 6-5/8" diameter
vent (see page for 22 details).
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Installation
40' (max)
35 feet
30 feet
25 feet
20 feet
15 feet
10 feet
5 feet
0 feet
(for qualified installers only)
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
4 0 7 0 6 2 0
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
This is considered a
vertical elbow
3 1
40' (max)
35 feet
30 feet
25 feet
20 feet
15 feet
10 feet
5 feet
0 feet