Installation Example - Build-Out (Dog-House) with Hor. Termination
The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.

Side View

See "Vent Termination"
siding by 1/16" - you may wish to
* Travis Ind. MIn. Vent Kit (SKU 98900168)
Includes a 4" section and horizontal termination.
NOTE FOR 2 x 4 EXTERIOR WALLS:
When installed with a 2x4 exterior wall, the
termination may not fit flush against the exterior
wall. You may wish to place framing around the
termination to fill the gap.
Top View
NOTE:
1/2" Clearance to sides
and back of fireplace.
Travis Industries
Installation
for full requirements.
The cap overlaps the exterior
make a flashing for this area.
Horizontal Termination*
4" Section*
(for qualified installers only)
SIDE OF FIREPLACE
Firestop
Insulation
Drywall
Optional Tile
4 0 7 0 6 2 0
Drywall
Optional Tile
NOTE:
In colder climates the fireplace may
require an insulated enclosure.
NOTE: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
Vapor
Barrier
100-01188_000