Rear Vent Config. W Horizontal Term. (W Vertical Rise); Rear Vent Configuration With Horizontal Termination (With Vertical Rise) - Travis Industries 564 Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for 564:
Table of Contents

Advertisement

2 8
Rear Vent Configuration with Horizontal Termination (with vertical
rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Only one horizontal elbow may be used.
22' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
Installation
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 2
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
(for qualified installers only)
Exhaust Restrictor # 6
Intake Restrictor # 2
Diffuser Position # 2
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
4 0 7 0 6 2 0
22' (max)
20 feet
15 feet
10 feet
5 feet
This is considered a
vertical elbow
0 feet
100-01188_000