Other Functions - Daikin SiENBE07-618_C Service Manual

C-series inverter pair duct connected type
Table of Contents

Advertisement

SiENBE07-618_C

1.10 Other Functions

1.10.1 Hot-Start Function
In order to prevent the cold air blast that normally comes when heating operation is started, the
temperature of the indoor heat exchanger is detected, and either the airflow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat is turned ON.
1.10.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote control, the unit emits a signal receiving
sound.
1.10.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
„ Press this button once to start operation. Press once again to stop it.
„ This button is useful when the remote control is missing or the battery has run out.
„ The operation mode refers to the following table.
<Forced operation mode>
Forced operation mode can be started by pressing the ON/OFF button for 5 to 9 seconds while
the unit is not operating.
Refer to "Forced operation mode" on page 42 for detail.
Note:
When the ON/OFF button is pressed for 10 seconds or more, the forced operation is stopped.
1.10.4 Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts automatically when the power is restored in the same condition as before the
power failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
Function and Control
Mode
Cooling Only
COOL
Heat Pump
AUTO
Temperature setting
22ºC
25ºC
ON/OFF button
(R4133)
Main Functions
Airflow rate
Automatic
Automatic
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents