Installation procedures
Before you begin
• All dispensers must be installed level in both directions to ensure proper operation
• Required ventilation and recommended service clearances:
• Countertop and wall mount models with Satellite-fi ll icemaker (C/E25CR400A/W, C/E25HR400A/W,
C/E50CR400A/W, C/E50HR400A/W) — none. 305mm (12") at top recommended for service
• Countertop and wall mount models with integral icemaker (C/E25CT400A/W, C/E25HT400A/W,
C/E50CT400A/W, C/E50HT400A/W) — 153mm (6") at top. 153mm (6") each side recommended for service
• Freestanding models (C/E25FB400A/W, C/E50FB400A/W) — 102mm (4") at rear. 305mm (12") at top
recommended for service
• All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser. See
counter cut-out on page 9 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where
utilities will exit through back of dispenser, refer to back view drawings.
• Wall mount models are designed for use above sinks or custom drain pans, and are not normally equipped with
integral drain pans. Front of sink should be a minimum of 584mm (23") from back wall. Connection of utilities through
the back for wall mount units is the same as shown in drawings for countertop models except that the drain pan is
absent.
• SensorSAFE dispensers are shipped with a plastic, protective fi lm on sensor lenses. For proper operation,
plastic fi lm must be removed after installation.

Installing freestanding dispensers

1.
Carefully tip dispenser back to expose underside and block up in place.
Do not tilt unit further than 30° off vertical plane.
!
2. Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking
care to seat legs securely against underside of dispenser.
3. Position dispenser in desired location and adjust legs to level in both directions.
4. Connect water supply to 10mm (3/8") OD push-in fi tting on back of dispenser (Fig. 1A).
5. Remove 19mm (3/4") dispenser drain line plug from back of unit and discard. Connect separate drain lines
to 19mm (3/4") FPT dispenser drain fi tting (Fig. 1B), and 19mm (3/4") MPT icemaker drain fi tting (Fig. 1C) on
back of dispenser.
6. Run drain lines to wall or fl oor drain. Provide an air break between the drain lines and drain. If icemaker
drain fi tting is below an intended wall drain, a condensate pump must be used.
7. If icemaker is a water-cooled unit, connect water-cooled condenser supply line to 10mm (3/8") FPT
condenser inlet fi tting on back of dispenser (Fig.1D).
Note: Do not run condenser supply water through icemaker water fi lter system.
8. Connect condenser drain line to 19mm (3/4") FPT condenser outlet fi tting on back of dispenser (Fig. 1E).
Important: Do not connect condenser drain line to any other drain lines.
9. Install appropriate plug on provided cord and insert into wall socket. Refer to wiring diagrams (p.18, 19).
10. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover to drop
approximately 10mm (3/8") and pull forward.
7

Advertisement

Table of Contents
loading

Table of Contents