Toshiba GD-1210 Service Manual page 83

Toshiba facsimile service manual
Hide thumbs Also See for GD-1210:
Table of Contents

Advertisement

The relation between the signals and sound volume is as follows.
Sound volume
VOLSEL2
Max. (7)
(6)
(5)
(4)
(3)
(2)
Min. (1)
Silent (0)
The monitoring signal whose volume is controlled by IC9 [IC2] is amplified by the OP amplifier (IC10
[IC1]), then output to the speaker.
Signal Name
Type
SP-SEL
O
MON
O
VOLSEL0-2
O
* Values in [ ] are for GD-1250/1270 in case that the descriptions vary between GD-1210 and GD-
1250/1270.
© 2006 - 2011 TOSHIBA TEC CORPORATION All rights reserved
VOLSEL1
LOW
LOW
LOW
LOW
LOW
HIGH
LOW
HIGH
HIGH
LOW
HIGH
LOW
HIGH
HIGH
HIGH
HIGH
Active
H
Line/Tone Selection Signal
H
Ring/Tone Selection Signal
H
Speaker Volume Control Signals 0-2
4 - 15
08/04
VOLSEL0
LOW
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
Description
Destination
IC3
IC3
IC9 [IC2]
GD-1210/1250/1270/1160/1260
ELECTRICAL CIRCUITS
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gd-1250Gd-1270Gd-1160Gd-1260