Troubleshooting - Lopi 1750i Inbuilt Owner's Manual

Wood-burning masonry fireplace insert
Table of Contents

Advertisement

18

Troubleshooting

Problem
Smoke Enters Room During
Start-Up
Kindling Does Not Start - Fire
Smolders
Smoke Enters Room While Re-
Loading
Stove Does Not Burn Hot Enough
Blower Does Not Run
Stove Does Not Burn Long
Enough
© Travis Industries
Operating Your Appliance
Possible Cause
Open the air control (pg. 15).
Cold Air Blockage - burn a piece of newspaper to
establish a draft.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Open the air control (pg. 15).
Not enough starter paper - use additional newspaper if
necessary.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Open the air control before opening the door (pg. 15).
Let the air stabilize before fully opening the door.
Then open the door approximately 1 inch (26mm). Let
air go into the firebox for a few seconds. Once the
smoke appears to be flowing up the chimney
consistently, open the door.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more piping or a draft-inducing cap may help.
Wood is Wet - see the section "Selecting Wood" on
page 17 for details on wood.
Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more piping or a
draft-inducing cap may help.
Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.
Electricity is cut to the Blower - Check the household
breaker or fuse to make sure it is operable.
Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
20 for details.
Check the ash bed for coals. Often, coals are still
glowing under a slight bed of fly-ash. By raking these
into a pile you can re-start your stove quickly.
100-01280