Download Print this page

Sony MVC-FD100H Service Manual page 75

Digital still camera
Hide thumbs Also See for MVC-FD100H:

Advertisement

16. CCD Black Defect Compensation
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3: Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
1
2
F
DF
3
F
DF
4C
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
9
6
01
79
10
6
30
01
11
6
07
12
6
01
8D
13
6
02
14
6
55
15
6
01
00
16
F
DF
5A
17
6
01
89
18
6
02
19
6
55
Note 4: The adjustment data will be automatically input to page:
7, address: 60 to 87.
RadarW
RadarW
RadarW
RadarW
RadarW
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Note down the data.
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button.
(Note 4)
Check the data changes to
"01".
Check the data.
00 to 0A : Normal
0B to FF : Defective
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Check the data.
00: Normal
01 to FF: Defective
MVC-FD100/FD100H/FD200/FD200H
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
30
4
6
91
5
F
DF
6
5-31
Procedure
00
Press PAUSE button.
00
00
00
Set data noted down at step
2, and press PAUSE button.
Release the data setting
performed at step 1. (Refer to
page 5-16)

Advertisement

loading

This manual is also suitable for:

Mvc-fd100Mvc-fd200hMvc-fd200