MVC-FD100/FD100H/FD200/FD200H
15. CCD White Defect Compensation
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The"CCD White Defect Compensation" should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
1
2
F
DE
3
F
DE
4
F
E3
5
F
E3
6
6
01
7
6
02
8
6
55
9
6
01
10
F
DE
11
F
E3
12
6
01
13
6
02
14
6
55
Note 3: The adjustment data will be automatically input to page:
7, address: 88 to FF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
F
DE
3
F
E3
4
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Not required
Displayed data of page: 6,
address: 55
Adjusting remote commander
7
88 to FF
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Note down the data.
1E
Press PAUSE button.
Note down the data.
0E
Press PAUSE button.
Press PAUSE button.
8B
(Note 3)
Check the data changes to
"01".
Check the data.
00 to 7F: Normal
80 to FF: Defective
00
Press PAUSE button.
0F
Press PAUSE button.
60
Press PAUSE button.
87
Press PAUSE button.
Check the data changes to
"01".
Check the data.
00: Normal
01 to FF: Defective
Procedure
00
Press PAUSE button.
Set data noted down at step
3, and press PAUSE button.
Set data noted down at step
5, and press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-16)
5-30