1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of "VIDEO SYSTEM ADJUSTMENTS" are sat-
isfied.
Note: For "CAMERA SYSTEM ADJUSTMENTS", perform in
order of item numbers.
Data setting during camera system adjustments
Perform the following data setting before the camera system ad-
justments.
It is not necessary to perform the following data setting everytime
when you perform some items of camera system adjustments con-
tinuously unless the power is turned off. Only when the power is
turned off during this adjustments, perform the data setting again,
then continue the adjustments.
Set up setting:
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the SET UP setting to "PAL")
Data setting method:
Order Page Address Data
1
0
01
2
D
63
3
D
63
4
D
10
5
6
C1
6
5
F1
7
6
6C
8
9
F
38
10
F
C5
11
F
C6
12
F
C7
13
B
75
14
E
AE
15
9
5D
16
9
5E
Note 1: For the bit values, refer to "5-2. SERVICE MODE",
"2-3. 2. Bit value discrimination".
Note 2: Repeat the "Data setting method", if the power was turned
off and on during the "CAMERA SYSTEM ADJUST-
MENTS".
Note 3: Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
Procedure
01
Note down the data.
Set the bit value of bit 6 is
"1", and press PAUSE
button. (Note 1)
81
Press PAUSE button.
Check the data changes to
"02".
FF
01
Wait for 1 second.
B1
Press PAUSE button.
Press PAUSE button.
40
(FD100: TYPE PA only)
(Note 3)
Press PAUSE button.
5A
(FD100: TYPE PA only)
(Note 3)
Press PAUSE button.
4A
(FD100: TYPE PA only)
(Note 3)
00
Press PAUSE button.
Press PAUSE button.
F9
(FD100: TYPE SO only)
(Note 3)
82
Press PAUSE button.
22
Press PAUSE button.
After completing the camera system adjustments,
release the data setting:
Order Page Address Data
1
5
F1
2
6
6C
3
B
75
4
D
10
5
D
63
6
0
01
5-16
Procedure
00
00
10
Press PAUSE button.
00
Press PAUSE button.
Set the bit value of bit 6 is
"0", and press PAUSE
button. (Note 1)
00