12. Auto White Balance 3200K Check
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
of Page: 1
(Note 2)
Measuring Instrument
Adjusting remote Vectorscope
commander
Specified Value
R ratio:
3E00 to 4200
B ratio:
3E00 to 4200
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Checking method:
Order Page Address Data
1
2
3
E
52
4
E
52
45
5
6
01
0F
6
0
03
04
7
1
8
0
03
05
9
1
10
RadarW
RadarW
RadarW
RadarW
RadarW
Video terminal of
VIDEO OUT jack
(75 Ω terminated)
Fig. 5-1-18
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Perform "Picture Frame
setting".
(Refer to page 5-17)
Note down the data.
Press PAUSE button.
Press PAUSE button.
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
Check that the center of the
white luminance point within
the circle shown Fig 5-1-18.
MVC-FD100/FD100H/FD200/FD200H
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
03
3
E
52
4
5-27
Procedure
00
Press PAUSE button.
00
Set data noted down at step
3, and press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-16)
R-Y
B-Y
4mm
4mm
Fig. 5-1-18