MVC-FD100/FD100H/FD200/FD200H
8. Mixed Color Cancel Adjustment
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
Subject
Measurement Point
Measurering Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Displayed data of page: F, address: A0 of the adjusting
remote commander.
F:XX:A0
Adjusting method:
Order Page Address Data
1
2
3
6
01
4
6
01
5
6
02
6
F
A0
Note 3: The adjustment data will be automatically input to page:
F, address: A0 and A3.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
3
0
01
RadarW
RadarW
RadarW
CAMERA
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: F,
address :A0 (Note 2)
Adjusting remote commander
F
A0 to A3
Check data : Except 3. (Note 2)
Check data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Perform "Picture Frame
setting".
(Refer to page 5-17)
D7
Press PAUSE button.
Press PAUSE button.
D5
(Note 3)
Check the data changes to
"01".
Check that the check data
satisfies the specified value.
(Note 2)
Procedure
00
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-16)
00
9. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance Standard Data Input" is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
6
01
4
6
01
5
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
5-24
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
F
3A to 3D, 59
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-16)
Perform "Picture Frame
setting".
(Refer to page 5-17)
11
Press PAUSE button.
Press PAUSE button.
0B
(Note 3)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-16)