Factory Reset; Ssh - Secure Shell Access - Siemens A31003-D3000-M100-01-76A9 Administrator User Manual

Openscape series desk phone ip
Table of Contents

Advertisement

Administration

Factory Reset

3.20 Factory Reset
3.21 SSH – Secure Shell Access
192
Administration via WBM
Maintenance > Restart Phone
Related Topics
This function resets all parameters to their factory settings. A special reset
password is required for this operation: "124816".
Administration via WBM
Maintenance > Factory reset
Administration via Local Phone
|
--- Admin
|--- Maintenance
|--- Factory reset
Related Topics
The phone's operating system can be accessed via SSH for special trouble-
shooting tasks. Administration via DLS is also supported. Hereby, the adminis-
trator is enabled to use the built-in Linux commands. As soon as SSH access has
been enabled using the WBM, the system can be accessed by the user "admin"
for a specified time span. When this time span has expired, no connection is
possible any more. The user "admin" has the following permissions:
Log folder and files: read only
User data folder and files: read/write access
Opera deploy folders and files: read only
Version folder: read/write access; version files: read only
INFO: It is not possible to logon as root via SSH.
When Enable access is enabled, and the parameters described underneath are
specified, SSH access is activated. By default, SSH access is disabled.
With the Session password parameter, a password for the "admin" user is
created. This password is required. It will be valid for the time span specified in
the parameters described underneath.
OpenScape Desk Phone IP, Phone Administration, Administrator Documentation