The following screen is displayed and the printer begins testing the parallel hardware for
the first time.
Parallel Wrap
P:###### F:#####
Terminology:
P:###### represents the number of times the test has passed (finished
successfully). Initially 000000 is displayed for ######. The maximum pass count is
999,999.
F:##### represents the number of times the test has failed (finished with errors).
Initially 00000 is displayed for #####. The maximum fail count is 99,999.
The power indicator blinks indicating the test is in process. The printer continually runs
the same test until cancelled from the operator panel (by pressing Return or Stop).
Each time the test finishes, the screen is updated with the result. If the test passes, then
the Pass Count is incremented by 1. However, if the test fails, then one of the following
failure messages is displayed for approximately 3 seconds and then the Fail Count is
incremented by 1.
Sync Busy Error
Byte Interrupt Request Error
Strobe Interrupt Request Error
Init Fall Error
Init Busy Error
Init Rise Error
Host Busy Error
RAM Data FF Error
RAM Data AA Error
RAM Data 00 Error
RAM Data 55 Error
DMA Count Error
DMA Address Error
DMA Interrupt Error
DMA Memory Error
DMA Background Error
Clear Init Rise Error
False Init Rise Error
False Init Fall Error
Autofeed Rising Interrupt Error
Clear Autofeed Rise Error
False Autofeed Rise Error
Autofeed Falling Interrupt Error
Clear Autofeed Fall Error
Once the maximum pass count or fail count is reached, the test is stopped and the final
test results are displayed. Press Return or Stop to exit the test.