Maintenance; Auto Descending Panel Page 1 - Mitsubishi Electric Mr.Slim PAR-30MAA Technical Manual

Ma remote controller
Hide thumbs Also See for Mr.Slim PAR-30MAA:
Table of Contents

Advertisement

Maintenance

Auto descending panel
Button operation
[ 1 ]
Maintenance menu
Auto descending panel
Manual vane angle
Main menu:
Cursor
[ 2 ]
Auto descending panel
Ref. address
Unit No.
Operation
Down / Up
Keep clear, panel descending.
Press Check for Unit No.
Input display:
Cur.
Address
Auto descending panel
Ref. address
Unit No.
Operation
DOWN
Panel will stop in 30 sec.
Keep clear, panel descending.
Cur.
Address
Select "Maintenance" from the Main menu (refer to page 17), and press the
button.
Select "Auto descending panel" with the F1 or F2 button, and press the
button.
* When using the auto descending panel, always set the "Address" and "Unit
No." with "Service" – "Function setting".
Move the cursor to "Ref. address", "Unit No." or "Operation" with the F1
button to select.
All
Select the refrigerant address and the unit number for the units to whose
Check
falls panel, with the F2 or F3 button, and press the
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 
• Operation: Down / Up
Press the F button to confirm the unit.
<Confirmation of target unit>
/ UP
If the unit being set is unknown, make the setting and then press the F but-
ton to confirm.
The air conditioner which is blowing downward is the target air conditioner.
Check
Navigating through the screens
• To go back to the Main menu ..................
• To return to the previous screen ..............
OFF
Main
button.
button
button
1

Hide quick links:

Advertisement

Table of Contents
loading