2. Schedule timer
Item
Setting Display City multi Mr.slim
Timer
Weekly timer
Setting the energy-
saving operation
schedule *2
3. Restriction
Item
Setting Display City multi Mr.slim
Enable / prohibit
manual operation
Operation lock
Setting the temp
range restriction
Automatic return to
the preset tem-
perature
Password
4. Others
Item
Setting Display City multi Mr.slim
Contrast
Manual vane angle
*2
Service menu *2
External input
External output
*2 The supported functions vary depending on the unit model.
Contents
Use to set the operation On / Off times.
Time can be set in 5-minute increments.
*Clock setting is required.
Use to set the Auto-Off time.
Time can be set to a value from 30 to 20 in 10-minute incre-
ments.
Use to set the weekly operation On / Off times.
Up to eight operation patterns can be set for each day.
*Clock setting is required.
*Not valid when the On/Off timer is enabled.
Set the start/stop times to operate the units in the energy-save
mode for each day of the week,and set the energy-saving rate.
Up to four energy-save operation patterns can be set for each
day. Time can be set in 5-minute increments.
Energy-saving rate can be set to a value from 0% and 90% in
10% increments.
Contents
The ON / OFF, operation mode, preset temperature and filter
sign reset operations from the centrally controlled settings are
prohibited.The corresponding icon lights when prohibited.
The ON / OFF, mode, set temperature and vane operations can
be prohibited.
Use to restrict the preset temperature range.
Use to get the units to operate at the preset temperature after
performing energy-save operation for a specified time period.
Time can be set to a value from 30 and 120 in 10-minute incre-
ments.
*This function will not be valid when the preset temperature
ranges are restricted.
An adminiatrator password (required for setting schedule, etc.)
ans maintenance password (required for Test run and Function
selection, etc.).
Contents
Use to adjust screen contrast.
Use to set the vane angle for each vane to a fixed position.
Test run,Function setting, Refrigerant leak check, Smooth main-
tenance, Request code and Eroor history support.
External input is not allowed
External output is not allowed
Required
password
A
A
A
A
Required
password
A
A
A
A
A / M
Required
password
89