1-9. Settings for External Editors
1-9-1.
Time Code Settings for Recorder
When editing with an editor capable of the 1st-edit (BVE-2000)
. Time code operation block on the front panel
INT/EXT switch
PRESET/REGEN switch
F-RUN/R-RUN switch
When editing directly from VTR to VTR
n
Make sure that the setting of ITEM-610 on the setup menu is as follows;
. ITEM-610: REGEN CONTROL MODE 8
. Time code operation block on the front panel
INT/EXT switch
PRESET/REGEN switch
F-RUN/R-RUN switch
1-9-2.
VTR Constant Settings for External Editors
The following constants are standard for each type and system listed.
When using an external editor which requires the VTR constants, use the settings listed. VTR constants
must also be set when switching between the 525 and 625 line systems.
System
525/60 System
625/50 System
m
1. Set the data No. 8 of VTR CONSTANT 1 to 0A for the following editors.
. BVE-900
ROM version 1.08 or lower
. BVE-600
ROM version 1.01 or lower
2. If the unit is controlled by the editor, be sure to set ITEM-401 on the setup menu as follows;
. ITEM-401: FUNCTION MODE AFTER CUE-UP
DNW-A28
DNW-A28P
8 INT
8 PRESET
8 F-RUN
0: auto edit
8 INT
8 PRESET
8 R-RUN
VTR CONSTANT 1
Data No.
1
2
3
4
5
B0 4D 00 96
07 07 04 8B
B1 4D 00 7D
07 07 04 8B
VTR CONSTANT 2
Data No.
6
7
8
1
2
3
4
0A 08 FB 00 8D 3D FF 5A
0A 07 FB 00 8F 4B FF 4B
Values are represented in hexadecimal