Operation Data - Toshiba RAS-22N3KV2-A Service Manual

Split type air conditioners
Table of Contents

Advertisement

7-2. Operation Data

<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/24
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/15
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 7.5 m
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
0.9 to 1.1
11 to 13
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
2.6 to 2.8
42 to 44
Indoor
fan mode
T2 (°C)
41 to 43
High
Indoor
fan mode
T2 (°C)
0 to 2
High
20
FILE NO. SVM-13003
Outdoor
Compressor
fan mode
revolution
(rps)
High
74
Outdoor
Compressor
fan mode
revolution
(rps)
High
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-22n3av2-a

Table of Contents