Indoor Fan Motor Control - Toshiba RAS-22N3KV2-A Service Manual

Split type air conditioners
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respectively.
(Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ °C ]
+2.5
a
+2.0
b
+1.5
+1.0
c
d
+0.5
e
Tsc
(Table 1) Indoor fan air flow rate
Fan speed
COOL
level
WF
WE
WD
WC
H
WB
M+
WA
W9
M
W8
W7
L+
W6
L
W5
L-
W4
UL
W3
SUL
W2
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3 : Fan speed = [(M +) –L] x 3/4 + L
*3
*4 : Fan speed = [(M +) –L] x 2/4 + L
*4
*5 : Fan speed = [(M +) –L] x 1/4 + L
*5
(Linear approximation
L(W6)
from M+ and L)
Fan speed
HEAT
DRY
(rpm)
UH
1250
H
1250
M+
1250
1200
M
1050
1020
L+
980
L
850
L-
L+
810
L
800
UL
L-
760
UL
700
SUL
650
SUL
500
500
(Fig. 1)
Fan speed
W6
(L + M) / 2
W9
(M + H) / 2
WC
(Fig. 2)
Air flow rate
3
(m
/h)
1156
1156
1156
1101
938
902
858
702
659
648
605
540
485
324
324
27
FILE NO. SVM-13003
Description
∗ ∗ ∗ ∗ ∗ Symbols
∗ ∗ ∗
UH: Ultra High
H : High
M+: Medium+
M : Medium
L+ : Low+
L : Low
L- : Low–
UL : Ultra Low
SUL : Super Ultra Low
* The values of fan speed and air
flow volume indicate on he table
are measured when the louver is
inclined downward.
Fan speed and air flow volume
broadly very with position of louver
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed leve
shown in Fig. 2 and Table 1
according to the setup tempera
ture, room temperature, and
heat exchanger temperature.