If the Menu key is
pressed menu change.
T2 POS
0 mm
*
T2 TBL
No. 3
*
EF POS
0 mm
*
EF TBL
No. 3
*
CH ADJ
ENABLE *
SB2 ADJ
ENABLE *
CH VOLT
0
*
SB2 VOLT
0
*
CH V ADJ
0
*
CH V MAX
0
*
Y103920-3
Press the Value+ or Value- key.
0 mm *
+1 mm
Press the Value+
or Value- key.
˜
+7 mm
-8 mm
˜
-1 mm
No. 1
No. 2
Press the Value+
No. 3 *
or Value- key.
0 mm *
+1 mm
Press the Value+
or Value- key.
˜
+7 mm
-8 mm
˜
-1 mm
No. 1
No. 2
Press the Value+
No. 3 *
or Value- key.
CH ADJ
DISABLE
Press the Value+
or Value- key.
SB2 ADJ
DISABLE
Press the Value+
or Value- key.
+3
+2
Press the Value+
+1
or Value- key.
0
*
- 1
- 2
- 3
+3
+2
Press the Value+
+1
or Value- key.
0
*
- 1
- 2
- 3
+5
+4
Press the Value+
+3
or Value- key.
+2
+1
0
*
- 1
- 2
- 3
- 4
- 5
0
*
- 1
Press the Value+
- 2
or Value- key.
Service Manual
Sets the amount of feeding paper from the 2nd tray.
(Sets the amount to TOF position).
Selects the download table for the 2nd tray.
Sets the amount of feeding paper from Multi Purpose
Feeder. (Sets the amount to TOF position.)
Selects the download table for the Multi Purpose Feed-
er.
Sets CH's voltage setting adjustment logic Enable/Dis-
able.
Sets SB2's voltage setting adjustment logic Enable/Dis-
able.
Changes the CH's default voltage.
Changes the SB2's default voltage.
Changes the CHSUB's default voltage (for the drum ro-
tations at 18PPM).
Changes the CHSUB's default voltage (for the drum ro-
tations at 8PPM).