4.6.4
Transmission Problems
Does the ID display?
Does the Verification Stamp
operate?
Is the copy quality OK?
Any other problems?
START
No
Yes
No
Yes
No
Yes
Yes
No
END
1. No ID function at the remote unit.
2. The ID is not set for the remote unit.
1. Set "STAMP=ON"
2. Check CN3 (SCA/SCB PCB).
3. Replace the Stamp Solenoid.
4. Replace the SCA/SCB PCB.
Make a copy and refer to Sect. 4.4.16
See Sect. 4.3 (Troubleshooting using
information codes).
Troubleshooting