Parameter; Parameter List - Mitsubishi Electric FR-A700 Technical Manual

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

2.1

Parameter list

2.1.1
FR-A700
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change and check can be made from the
operation panel (FR-DU07).
indicates simple mode parameters. (initial setting is extended mode)
• The parameters marked with
in the table allow its setting to be changed during operation even if 0 (initial value) is
set in [Pr. 77 Parameter write selection].
[Pr.]
Name
Torque boost
0 to 30%
0
Maximum frequency
0 to 120Hz
1
Minimum frequency
0 to 120Hz
2
Base frequency
0 to 400Hz
3
Multi-speed setting (high speed)
0 to 400Hz
4
Multi-speed setting (middle speed)
0 to 400Hz
5
Multi-speed setting (low speed)
0 to 400Hz
6
Acceleration time
0 to 3600/360s
7
Deceleration time
0 to 3600/360s
8
Electronic thermal O/L relay
0 to 500/0 to 3600A
9
10
DC injection brake operation frequency
0 to 120Hz, 9999
11
DC injection brake operation time
0 to 10s, 8888
12
DC injection brake operation voltage
0 to 30%
13
Starting frequency
0 to 60Hz
14
Load pattern selection
0 to 5
15
Jog frequency
0 to 400Hz
16
Jog acceleration/deceleration time
0 to 3600/360s
17
MRS input selection
0, 2, 4
18
High speed maximum frequency
120 to 400Hz
19
Base frequency voltage
0 to 1000V, 8888, 9999
Acceleration/deceleration reference
20
1 to 400Hz
frequency
21
Acceleration/deceleration time increments 0, 1

PARAMETER

Minimum Setting
Refer to
Setting Range
Initial Value
Increments
0.1%
6/4/3/2/1%
*1
0.01Hz
120/60Hz
*2
0.01Hz
0Hz
0.01Hz
60Hz
0.01Hz
60Hz
216, 395
0.01Hz
30Hz
216, 395
0.01Hz
10Hz
216, 396
0.1/0.01s
5/15s
*3
0.1/0.01s
5/15s
*3
Rated inverter
0.01/0.1A
*2
*2
current
0.01Hz
3Hz
325, 328
0.1s
0.5s
325, 328
0.1%
4/2/1%
*4
0.01Hz
0.5Hz
1
0
0.01Hz
5Hz
0.1/0.01s
0.5s
215, 234
1
0
0.01Hz
120/60Hz
*2
0.1V
9999
0.01Hz
60Hz
1
0
120
• Symbols in the table indicate parameters which function when an option is mounted.
...... FR-A7AX,
...... FR-A7AP,
...... FR-A7NC,
...... FR-A7NP,
• These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485
communication.
• Symbols in the control mode-based correspondence table indicate the following;
: Usable parameter
×: Unusable parameter
∆: Parameters available only during position control set by parameter
• Symbols in the parameter copy, parameter clear, and all parameter clear columns indicate the following;
: Valid
×:
Invalid
[Pr.]
Option
Page
244
0
232
1
232
2
244
3
4
5
6
234
7
234
8
379
9
10
11
328
12
232
13
244
14
215
15
16
56
17
232
18
244
19
234
20
234
21
....FR-A7AY,
..... FR-A7AR,
.....FR-A7AL,
...... FR-A7AZ,
....FR-A7ND,
..... FR-A7NL,
.....FR-A7NS,
..... FR-A7NF
Instruction Code
Control Mode-based Correspondence Table
Advanced
Vector control
magnetic
flux
vector
control
×
×
×
×
00
80
0
01
81
0
×
02
82
0
03
83
0
×
×
×
×
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
×
0A
8A
0
×
0B
8B
0
×
×
×
0C
8C
0
×
0D
8D
0
×
×
×
×
0E
8E
0
×
0F
8F
0
10
90
0
×
11
91
0
×
×
×
12
92
0
×
×
×
×
13
93
0
14
94
0
15
95
0
120
PARAMETER
Real sensorless
2
vector control
Speed
Torque
control
control
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents