1.4.31 USB connector

Connect the inverter and PC with USB cable and use FR
Configurator to make the inverter setup easily.
When using USB communication, set [Pr. 551 PU mode
operation command source selection = 3].
[Pr. ]
Name
USB communication
547
station number
USB communication check
548
time interval
USB communication specifications
Interface
Conforms to USB1.1
Transmission Speed:
12Mbps
Wiring length
Maximum 5m
A700
USB B connector (B receptacle)
Connector
E700
USB mini B connector
(receptacle mini B type)
Power supply
Self-power supply
(1)
A700
Removal of cover
Place a flat-blade screwdriver,
etc. in a slot and push up the
cover to open.
A700 E700
(A700)(E700)
Initial
Setting
Value
Range
0
0 to 31
0
9999
0.1 to 999.8s
9999
USB connector
USB cable
85
Parameter setting and monitoring are performed using FR
Configurator. Refer to the instruction manual of FR
Configurator for details.
It is recommended to fit a ferrite core to the USB cable to
reduce the effect of noises from the inverter.
Description
Specifies the inverter station number.
USB communication is enabled. However, the inverter will
come to an alarm stop (E. USB) if operation is changed to PU
operation mode.
Set the interval of communication check time.
If a no-communication state persists for longer than the
permissible time, the inverter will come to trip (E.USB).
No communication check
(2)
E700
USB
USB
cable
connector
<How to open the USB connector cover>
Pull the cover in the direction of arrow.Then turn it upward.
SPECIFICATIONS