Downloading The Firmware From The Usb Memory - Kyocera FS-1350DN Service Manual

Hide thumbs Also See for FS-1350DN:
Table of Contents

Advertisement

2H4

(2) Downloading the firmware from the USB memory

To download data written in a USB memory to the printer, proceed as explained in this section.
CAUTION
Downloading firmware takes several minutes. Do not turn power off during downloading. If downloading is interrupted by
an accidental power failure, etc., the control PWB may have to be replaced.
Procedure
1. Turn printer power off.
2. Insert the USB memory to the PC's USB
slot.
3. Copy the firmware files to download to the
root directory of the USB memory.
4. Remove the USB memory from the PC's
USB slot.
5. Insert the USB memory into the printer's
USB memory slot.
6. Turn printer power on.
7. When message display (1) is displayed to
detect firmware in the USB memory.
8. Message display (2) is displayed during
downloading.
9. When message display (3) is displayed to
indicate downloading is finished.
1-6-2
USB memory
slot
USB memory
Figure 1-6-2
Message display
supervisor mode
(1)
supervisor mode
(2)
USB data reading
2H4_1000.000.024
(3)
[E1F9]
Product code
2H4= This printer
Firmware category
10: Engine
30: System (Main)
31: System (BROM)
Supplement (Normally: 00)
Classification (Normally: 0)
Update history
Build number
Checksum
Figure 1-6-3