5. Remove the transfer roller's shaft from the
both transfer bushes.
6. Remove the gear Z16 from the transfer
roller.
7. Check or replace the transfer roller and refit
all the removed parts.
Caution: When refitting the transfer roller, be
careful about following point.
Push the release lever to raise the lever
end, then insert the front of gear Z16 under
the release lever end.
Transfer roller
Shaft
Transfer bush
Gear Z16
Gear Z16
Release lever
Transfer bush
Shaft
Transfer bush
Transfer roller
Figure 1-5-20
Transfer bush
Transfer roller
Figure 1-5-21