Kyocera FS-1350DN Service Manual page 115

Hide thumbs Also See for FS-1350DN:
Table of Contents

Advertisement

Connector
Pin
1
VBUS
YC4
Connected
2
HUSBDN
to the opera-
3
HUSBDP
tion panel
PWB
YC7
1
+5V
Connected
2
+3.3V1
to the opera-
3
FPDAT
tion panel
4
FPDIR
PWB
5
FPCLK
6
SGND
FPRSTN
7
YC9
1
+24V3
Connected
2
PGND
to the laser
3
PLGDRN
scanner unit
4
PLGRDY
5
PLGCLK
6
PDN
7
SGND
8
VDON
9
VDOP
10
OUTPEN
11
SAMPLEN
12
+3.3V2
YC330
1
+3.3V2
Connected
2
SGND
to the MP
3
HANDSN
paper sen-
sor
YC331
1
+24V3
Connected
2
PGND
to the main
3
MMOTRDYN
motor
4
MMOTCLK
5
REMOTEN
YC332
1
+3.3V2
Connected
2
SGND
to the paper
3
PAPER
sensor
YC333
1
+3.3V2
Connected
2
SGND
to the exit
3
EXITN
sensor
YC334
1
+24V3
Connected
2
REGDRN
to the regis-
3
+24V3
tration
4
FEDDRN
clutch,
5
+24V3
paper feed
6
DLPDRN
clutch and
developing
clutch
Signal
I/O
O
5 V DC
I/O
(Differential signal) Data signal
I/O
(Differential signal) Data signal
O
5 V DC
O
3.3 V DC
O
0/3.3 V DC (pulse) Operation panel PWB data signal
O
3.3/0 V DC
O
0/3.3 V DC (pulse) Operation panel PWB clock signal
-
-
O
3.3/0 V DC
O
24 V DC
-
-
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Polygon motor clock signal
I
0/3.3 V DC (pulse) Horizontal synchronizing signal
-
-
O
0/3.3 V DC (pulse) Video data signal (+)
O
0/3.3 V DC (pulse) Video data signal (-)
O
0/3.3 V DC
O
0/3.3 V DC
O
3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
24 V DC
-
-
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Main motor clock signal
O
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
O
24 V DC
O
0/24 V DC
Voltage
5 V DC power source
5 V DC power source
3.3 V DC power source
Operation panel PWB communication direct signal
Ground
Operation panel PWB reset signal
24 V DC power source
Ground
Polygon motor: On/Off
Polygon motor ready signal
Ground
Laser output enable signal
Sample/hold timing switching signal
3.3 V DC power source
3.3 V DC power source
Ground
MP paper sensor: On/Off
24 V DC power source
Ground
Main motor ready signal
Main motor: On/Off
3.3 V DC power source
Ground
Paper sensor: On/Off
3.3 V DC power source
Ground
Exit sensor: On/Off
24 V DC power source
Registration clutch: On/Off
24 V DC power source
Paper feed clutch: On/Off
24 V DC power source
Developing clutch: On/Off
Description
2H4
2-3-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents